Signal‐to‐noise analysis of cerebral blood volume maps from dynamic NMR imaging studies
- 1 May 1997
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 7 (3) , 528-537
- https://doi.org/10.1002/jmri.1880070313
Abstract
The use of cerebral blood volume (CBV) maps generated from dynamic MRI studies tracking the bolus passage of paramagnetic contrast agents strongly depends on the signal‐to‐noise ratio (SNR) of the maps. The authors present a semianalytic model for the noise in CBV maps and introduce analytic and Monte Carlo techniques for determining the effect of experimental parameters and processing strategies upon CBV‐SNR. CBV‐SNR increases as more points are used to estimate the baseline signal level. For typical injections, maps made with 10 baseline points have 34% more noise than those made with 50 baseline points. For a given peak percentage signal drop, an optimum TE can be chosen that, in general, is less than the baseline T2. However, because CBV‐SNR is relatively insensitive to TE around this optimum value, choosing TE ≈ T2 does not sacrifice much SNR for typical doses of contrast agent. The TR that maximizes spin‐echo CBV‐SNR satisfies TR/T1 ≈ 1.26, whereas as short a TR as possible should be used to maximize gradient‐echo CBV‐SNR. In general, CBV‐SNR is maximized for a given dose of contrast agent by selecting as short an input bolus duration as possible. For image SNR exceeding 20–30, the Γ‐fitting procedure adds little extra noise compared with simple numeric integration. However, for noisier input images, as can be the case for high resolution echo‐planar images, the covarying parameters of the Γ‐variate fit broaden the distribution of the CBV estimate and thereby decrease CBV‐SNR. The authors compared the analytic noise predicted by their model with that of actual patient data and found that the analytic model accounts for roughly 70% of the measured variability of CBV within white matter regions of interest.Keywords
This publication has 16 references indexed in Scilit:
- Mr contrast due to intravascular magnetic susceptibility perturbationsMagnetic Resonance in Medicine, 1995
- A Single‐Step Method for Estimation of Local Cerebral Blood Volume from Susceptibility Contrast MRI ImagesMagnetic Resonance in Medicine, 1995
- Measurement of Relative Cerebral Blood Volume Changes with Visual Stimulation by ‘Double-Dose’ Gadopentetate-Dimeglumine-Enhanced Dynamic Magnetic Resonance ImagingInvestigative Radiology, 1994
- Assessment of Cerebral Blood Volume with Dynamic Susceptibility Contrast Enhanced Gradient-Echo ImagingJournal of Computer Assisted Tomography, 1994
- Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.Radiology, 1994
- Acute cerebral ischemia: evaluation with dynamic contrast-enhanced MR imaging and MR angiography.Radiology, 1992
- Susceptibility contrast imaging of cerebral blood volume: Human experienceMagnetic Resonance in Medicine, 1991
- Functional Mapping of the Human Visual Cortex by Magnetic Resonance ImagingScience, 1991
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988
- Indicator Transit Time Considered as a Gamma VariateCirculation Research, 1964