Solute Separations from Water by Dialysis. II. Separation of Phenol by Downstream Conjugation

Abstract
The dialysis of phenol through a permselective hydrophobia membrane into a solution sink of caustic (as a conjugating base) was evaluated as a method of extracting dilute contaminants from industrial effluent streams. A series of membranes for this service was characterized in a small rotating batch dialyzer and these results were used to evaluate a process configuration for handling a continuous feed of a prototype industrial effluent.

This publication has 3 references indexed in Scilit: