Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
Open Access
- 1 January 2008
- journal article
- research article
- Published by Korean Ophthalmological Society in Korean Journal of Ophthalmology
- Vol. 22 (1) , 18-25
- https://doi.org/10.3341/kjo.2008.22.1.18
Abstract
To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. Fifty-three eyes with an atypical birefringence pattern (ABP) based on SLP-VCC (28 glaucomatous eyes and 25 normal healthy eyes) were enrolled in this cross-sectional study. RNFL thickness was measured by both VCC and ECC techniques, and the visual field was examined by HVFA with 24-2 full-threshold program. The relationships between RNFL measurements in superior and inferior sectors and corresponding retinal mean sensitivity were sought globally and regionally with linear regression analysis in each group. Coefficients of the determination were calculated and compared between VCC and ECC techniques. In eyes with ABP, R2 values for the association between SLP parameters and retinal sensitivity were 0.06-0.16 with VCC, whereas they were 0.21-0.48 with ECC. The association of RNFL thickness with retinal sensitivity was significantly better with ECC than with VCC in 5 out of 8 regression models between SLP parameters and HVF parameters (P<0.05). The strength of the structure-function association was higher with ECC than with VCC in eyes with ABP, which suggests that the ECC algorithm is a better approach for evaluating the structure-function relationship in eyes with ABP.Keywords
This publication has 25 references indexed in Scilit:
- Structure-Function Relationship Is Stronger with Enhanced Corneal Compensation than with Variable Corneal Compensation in Scanning Laser PolarimetryInvestigative Opthalmology & Visual Science, 2007
- Scanning Laser Polarimetry with Variable Corneal Compensation in the Area of Apparently Normal Hemifield in Eyes with Normal-Tension GlaucomaOphthalmology, 2006
- Enhanced Imaging Algorithm for Scanning Laser Polarimetry with Variable Corneal CompensationInvestigative Opthalmology & Visual Science, 2006
- Relationships between Standard Automated Perimetry, HRT Confocal Scanning Laser Ophthalmoscopy, and GDx VCC Scanning Laser PolarimetryInvestigative Opthalmology & Visual Science, 2005
- Scanning Laser Polarimetry Using Variable Corneal Compensation in the Detection of Glaucoma with Localized Visual Field DefectsOphthalmology, 2005
- Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensationOphthalmology, 2005
- Quantitative assessment of structural damage in eyes with localized visual field abnormalitiesAmerican Journal of Ophthalmology, 2004
- The correlation between optic nerve head topographic measurements, peripapillary nerve fibre layer thickness, and visual field indices in glaucomaBritish Journal of Ophthalmology, 2003
- Effect of peripapillary chorioretinal atrophy on GDx parameters in patients with degenerative myopiaClinical & Experimental Ophthalmology, 2002
- Mapping the visual field to the optic disc in normal tension glaucoma eyes11The authors have no proprietary interest in the development or marketing of any product or instrument mentioned in this article.Ophthalmology, 2000