Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery
Top Cited Papers
- 4 April 2003
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 21 (5) , 437-440
- https://doi.org/10.1002/uog.103
Abstract
Objective: To investigate the accuracy of intrapartum transvaginal digital examination in defining the position of the fetal head before instrumental delivery.Patients and Methods: In 64 singleton pregnancies undergoing instrumental delivery the fetal head position was determined by transvaginal digital examination by the attending obstetrician. Immediately after or before the clinical examination, the fetal head position was determined by transabdominal ultrasound by a trained sonographer who was not aware of the clinical findings. The digital examination was considered to be correct if the fetal head position was within ± 45° of the ultrasound finding. The accuracy of the digital examination was examined in relation to maternal and fetal characteristics.Results: Digital examination failed to define the correct fetal head position in 17 (26.6%) cases. In 12 of 17 (70.6%) errors the difference was ≥ 90° and in five (29.4%) the difference was between 45° and 90°. The accuracy of vaginal digital examination was 83% for occiput‐anterior and 54% for occiput‐lateral + occiput‐posterior positions. Logistic regression analysis demonstrated significant independent contributions in explaining the variance in the accuracy of vaginal examination for the station of the fetal head, the position of the fetal head and the experience of the examining obstetrician.Conclusions: Digital examination during instrumental delivery fails to identify the correct fetal head position in about one quarter of cases. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- Intrapartum fetal head position II: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the second stage of laborUltrasound in Obstetrics & Gynecology, 2002
- Intrapartum sonography to determine fetal head positionThe Journal of Maternal-Fetal & Neonatal Medicine, 2002
- Determination of fetal occiput position by ultrasound during the second stage of laborThe Journal of Maternal-Fetal & Neonatal Medicine, 2001
- Soft Versus Rigid Vacuum Extractor Cups for Assisted Vaginal DeliveryBirth, 2000
- Effect of Mode of Delivery in Nulliparous Women on Neonatal Intracranial InjuryNew England Journal of Medicine, 1999
- Neonatal subgaleal haematoma: Associated risk factors, complications and outcomeJournal of Paediatrics and Child Health, 1996
- Birth by vacuum extraction: Neonatal outcomeJournal of Paediatrics and Child Health, 1996
- Labour and delivery of ‘normal’ primiparous women: analysis of routinely collected dataBJOG: An International Journal of Obstetrics and Gynaecology, 1995
- Anal sphincter trauma during instrumental deliveryInternational Journal of Gynecology & Obstetrics, 1993
- THE IMPORTANCE OF FLEXION IN VACUUM EXTRACTOR DELIVERYBJOG: An International Journal of Obstetrics and Gynaecology, 1976