Imaging morphological details and pathological differences of red blood cells using tapping-mode AFM
- 1 January 2004
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biological Chemistry
- Vol. 385 (10) , 955-60
- https://doi.org/10.1515/bc.2004.124
Abstract
The surface topography of red blood cells (RBCs) was investigated under near-physiological conditions using atomic force microscopy (AFM). An immobilization protocol was established where RBCs are coupled via molecular bonds of the membrane glycoproteins to wheat germ agglutinin (WGA), which is covalently and flexibly tethered to the support. This results in a tight but non-invasive attachment of the cells. Using tapping-mode AFM, which is known as gentle imaging mode and therefore most appropriate for soft biological samples like erythrocytes, it was possible to resolve membrane skeleton structures without major distortions or deformations of the cell surface. Significant differences in the morphology of RBCs from healthy humans and patients with systemic lupus erythematosus (SLE) were observed on topographical images. The surface of RBCs from SLE patients showed characteristic circular-shaped holes with approx. 200 nm in diameter under physiological conditions, a possible morphological correlate to previously published changes in the SLE erythrocyte membrane.Keywords
This publication has 30 references indexed in Scilit:
- Dynamic force microscopy imaging of native membranesUltramicroscopy, 2003
- Scanning Probe Evolution in BiologyScience, 2003
- The application of atomic force microscopy to the study of living vertebrate cells in cultureMethods, 2003
- Molecular Recognition Studies Using the Atomic Force MicroscopePublished by Elsevier ,2002
- Impairment of genomic DNA binding to a putative dysfunctional receptor on erythrocytes independent of complement and antibodies in systemic lupus erythematosus.Virchows Archiv, 2000
- Observing single biomolecules at work with the atomic force microscope.Nature Structural & Molecular Biology, 2000
- Application of atomic force microscopy to microbial surfaces: from reconstituted cell surface layers to living cellsMicron, 2000
- The C3b/C4b receptor (CR1, CD35) on erythrocytes: methods for study of the polymorphismsMolecular Immunology, 1999
- A magnetically driven oscillating probe microscope for operation in liquidsApplied Physics Letters, 1996
- Interstitial immune complex nephritis in patients with systemic lupus erythematosusKidney International, 1975