Dried‐droplet probe preparation on AnchorChip™ targets for navigating the acquisition of matrix‐assisted laser desorption/ionization time‐of‐flight spectra by fluorescence of matrix/analyte crystals
- 24 March 2004
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (9) , 923-930
- https://doi.org/10.1002/rcm.1427
Abstract
We have developed a dried‐droplet probe preparation method for peptide mass fingerprinting by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS), which uses AnchorChip™ targets and α‐cyano‐4‐hydroxycinnamic acid (CHCA) as a matrix. Upon drying of a matrix and analyte mixture on the AnchorChip, salts and low molecular weight contaminants were pooled at the hydrophilic metal anchor, whereas 10–50 μm matrix/peptide crystals firmly adhered at the surface of a hydrophobic polymer and the entire target could be subsequently washed by submerging it in 5% formic acid for 2–3 min. Epifluorescence microscopy suggested that peptides were completely co‐localized with CHCA crystals at the AnchorChip surface. Fluorescent images of the probes were of good contrast and were background‐free, compared with images taken by a video camera built into the ion source. CHCA/peptide crystals were easy to recognize at the surface and peptide mass maps were acquired from them without further adjustment of the position of the laser beam. These crystals were remarkably stable towards the laser depletion and almost no matrix‐related ions were typically observed in the low m/z region of peptide mass maps. The sensitivity of the peptide mass mapping was at the low‐femtomole level. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 28 references indexed in Scilit:
- Role of Electrons in Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 2003
- Non‐specific, on‐probe cleanup methods for MALDI‐MS samplesMass Spectrometry Reviews, 2003
- Mass spectrometry-based proteomicsNature, 2003
- A new method to improve sensitivity and resolution in matrix‐assisted laser desorption/ionization time of flight mass spectrometryProteomics, 2003
- Protein identification with Teflon as matrix‐assisted laser desorption/ionization sample supportJournal of Mass Spectrometry, 2002
- Analysis of Proteins and Proteomes by Mass SpectrometryAnnual Review of Biochemistry, 2001
- MALDI Quadrupole Time-of-Flight Mass Spectrometry: A Powerful Tool for Proteomic ResearchAnalytical Chemistry, 2000
- Peptides adsorbed on reverse‐phase chromatographic beads as targets for femtomole sequencing by post‐source decay matrix assisted laser desorption ionization‐reflectron time of flight mass spectrometry (MALDI‐RETOF‐MS)Electrophoresis, 1997
- Improved Resolution and Very High Sensitivity in MALDI TOF of Matrix Surfaces Made by Fast EvaporationAnalytical Chemistry, 1994
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988