Validation of the INNO-LIA Syphilis Kit as a Confirmatory Assay forTreponema pallidumAntibodies
- 1 January 2000
- journal article
- clinical trial
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 38 (1) , 215-9
- https://doi.org/10.1128/jcm.38.1.215-219.2000
Abstract
The commercially available diagnostic tests for syphilis are mostly based on the use of extracted antigens ofTreponema pallidum. Pronounced cross-reactivities with other spirochete antigens are often reported. The aim of this study was to validate a novel multiparametric assay (the assay performed with the kit) INNO-LIA Syphilis for the confirmation of syphilis antibodies in a set of 840 documented human serum samples. All serum samples were previously tested at the French World Health Organization reference center for venereal diseases (Institute Alfred Fournier, Paris, France), with a consensus result provided for each sample. The study was conducted in two phases, with each phase involving a validation set (500 well-documented serum samples) and an exploratory set (340 serum samples) of serum samples, respectively. By measuring the sensitivity and specificity, we compared the result of the new assay with the consensus result on the basis of the results of a variable number of classical serological methods and clinical information when available. A sensitivity of 99.6% (95% confidence internal [CI], 98.5 to 99.9%) and a specificity of 99.5% (95% CI, 98.1 to 99.9%) were found for the new line immunoassay. Six of seven samples with indeterminate results by classical serology tested positive with the INNO-LIA Syphilis kit. This single multiparametric assay provides reliable confirmatory diagnostic information that must currently be obtained by the performance and interpretation of results of a combination of serological assays.Keywords
This publication has 21 references indexed in Scilit:
- Syphilis: Review with Emphasis on Clinical, Epidemiologic, and Some Biologic FeaturesClinical Microbiology Reviews, 1999
- Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screeningTransfusion, 1999
- SYPHILISDermatologic Clinics, 1998
- False-Negative Fluorescent Treponemal Tests and Confirmation of Syphilis InfectionThe Journal of Infectious Diseases, 1998
- Reactivity of recombinant treponema pallidum (r-Tp) antigens with anti-Tp antibodies in human syphilitic sera evaluated by ELISAJournal of Clinical Laboratory Analysis, 1997
- Are You Sure It's Syphilis? A Review of False Positive SerologyInternational Journal of STD & AIDS, 1995
- Laboratory diagnosis and interpretation of tests for syphilis.1995
- False-Positive Rapid Plasma Reagin Tests in Human Immunodeficiency Virus Infection and Relationship to Anti-Cardiolipin Antibody and Serum Immunoglobulin LevelsThe Journal of Infectious Diseases, 1994
- Evaluation of the fluorescent treponemal antibody-absorption (FTA-Abs) test specificity.Acta Dermato-Venereologica, 1991
- False-negative syphilis screening: The prozone phenomenon, nonimmune hydrops, and diagnosis of syphilis during pregnancyAmerican Journal of Obstetrics and Gynecology, 1990