Histological and histomorphometrical analysis of bioactive glass and fibre reinforced bioactive glass dental root implants
- 1 September 1988
- journal article
- research article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 15 (5) , 473-487
- https://doi.org/10.1111/j.1365-2842.1988.tb00183.x
Abstract
Bioactive glass has the ability to bond with bone, but it cannot be used as a load bearing device due to its limited mechanical properties. By reinforcing bioactive glass with a ductile second phase, a structurally reliable material is obtained. The aim of the present study was to evaluate histologically and morphometrically the interfacial behaviour of submerged composite dental root implants. Therefore, bulk and composite implants were subgingivally installed in the partially edentulous jaws of Beagle dogs and harvested after 4 and 16 months. Histologically, the connection between the implants and bone tissue could be clearly demonstrated. This bone connection is mainly located at the cortical bone level. In the vicinity of the infraalveolar nerve a fibrous tissue contact was found. It is shown that surgical trauma, motion at the glass to tissue interface, and gross ion dissolution from the material adversely affect the interfacial osteogenesis. If these factors are controlled, bone bonding is found over a larger area than in the initial area of contact between the implant and bone tissue. This means that bone grows out along the implant surface, starting from the initial contact area. No difference was observed between the interfacial behaviour of bulk bioactive glass and intact fibre reinforced bioactive glass implants.This publication has 23 references indexed in Scilit:
- Bioglass coatings and bioglass composites as implant materialsJournal of Biomedical Materials Research, 1985
- The interface of various glasses and glass ceramics with a bony implantation bedJournal of Biomedical Materials Research, 1985
- Materials, clinical and morphological evaluation of custom‐made bioreactive‐glass‐coated canine hip prosthesesJournal of Biomedical Materials Research, 1984
- Bioglass composites: a potential material for dental applicationBiomaterials, 1983
- The interface zone of inorganic implantsIn vivo: Titanium implants in boneAnnals of Biomedical Engineering, 1983
- The anchoring of glass ceramics of different solubility in the femur of the ratJournal of Biomedical Materials Research, 1980
- Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implantsJournal of Biomedical Materials Research, 1977
- Analysis of bioglass fixation of hip prosthesesJournal of Biomedical Materials Research, 1977
- Surface Staining of Sawed Sections of Undecalcified Bone Containing Alloplastic ImplantsStain Technology, 1977
- Bone formation at a ceramic implant interfaceCalcified Tissue International, 1971