Routine obstetric ultrasound: Effectiveness of cross‐sectional screening for fetal growth retardation
- 1 January 1986
- journal article
- research article
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 14 (1) , 17-22
- https://doi.org/10.1002/jcu.1870140105
Abstract
Sonographic detection of fetal growth retardation was evaluated on a sample of 778 patients routinely scanned over a 16‐month period. From the 29th week to term, the sensitivity of abdominal circumference measurement progressively increased from 41% to 88% (P < 0.01). Higher rates were achieved by using the biparietal diameter but false‐positive diagnoses were twice as frequent as with the abdominal measurements. When the limitations in precision of abdominal circumference were considered, the screening rate of this parameter increased about 16%. Moreover, 50% of the falsenegative diagnoses were made on fetuses weighing between the fifth and 10th centiles at birth. These diagnostic indices for biparietal diameter and abdominal circumference evaluated on a retrospective series proved to be lower than those reported for the prospective selected series. However, the results yielded by routine ultrasound were better than those obtained with clinical or traditional biochemical methods. These findings underline the importance of sonography not only in serial control of high‐risk pregnancies but also in cross‐sectional screening programs.Keywords
This publication has 18 references indexed in Scilit:
- Eenie, meenie, minie, mo … What do the data really show?American Journal of Obstetrics and Gynecology, 1982
- The use of ultrasound in the detection of intrauterine growth retardation: A reviewJournal of Clinical Ultrasound, 1982
- Comparison of abdominal circumference measurements by real‐time and b‐scan techniquesJournal of Clinical Ultrasound, 1981
- Screening for the small-for-dates fetus: a two-stage ultrasonic examination schedule.BMJ, 1980
- ULTRASOUND ASSESSMENT OF FETAL GROWTHBJOG: An International Journal of Obstetrics and Gynaecology, 1979
- The value of diagnostic ultrasound as a screening test for intrauterine growth retardation: Comparison of nine parametersAmerican Journal of Obstetrics and Gynecology, 1979
- A standard of fetal growth for the united states of AmericaAmerican Journal of Obstetrics and Gynecology, 1976
- Assessment of intrauterine growth retardation by diagnostic ultrasoundAmerican Journal of Obstetrics and Gynecology, 1976
- GROWTH OF THE FETAL BIPARIETAL DIAMETER DURING NORMAL PREGNANCYBJOG: An International Journal of Obstetrics and Gynaecology, 1971
- THE ASSESSMENT OF FETAL GROWTHBJOG: An International Journal of Obstetrics and Gynaecology, 1968