The interaction between magnetization transfer and blood‐oxygen‐level‐dependent effects
- 27 January 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 356-366
- https://doi.org/10.1002/mrm.20348
Abstract
Low‐power off‐resonance spin‐echo magnetization transfer (MT) imaging experiments with a long repetition time (TR) were performed on rat brain for a range of arterial PCO2 levels. The measured magnetization transfer ratio decreased with increased arterial PCO2 levels. When performing blood‐oxygen‐level‐dependent (BOLD) functional magnetic resonance imaging (fMRI)‐type data analysis in which signal intensities were normalized to the normocapnic state, the CO2‐based BOLD effect was much stronger with than without saturation. This increased effect is a consequence of the fact that the MT effect reduces the signal intensity in tissue more than in blood, thereby amplifying the contribution of the intravascular BOLD signal change to the overall BOLD effect. The results offer a potential approach to measure absolute cerebral blood volume in vivo and to amplify the BOLD effects for fMRI studies. Magn Reson Med 53:356–366, 2005.Keywords
This publication has 36 references indexed in Scilit:
- Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 TeslaMagnetic Resonance in Medicine, 2002
- Intervoxel Heterogeneity of Event-Related Functional Magnetic Resonance Imaging Responses as a Function of T1 WeightingNeuroImage, 2002
- Quantitative T1ρ and Magnetization Transfer Magnetic Resonance Imaging of Acute Cerebral Ischemia in the RatJournal of Cerebral Blood Flow & Metabolism, 2002
- In Vivo Determination of Absolute Cerebral Blood Volume Using Hemoglobin as a Natural Contrast Agent: An MRI Study Using Altered Arterial Carbon Dioxide TensionJournal of Cerebral Blood Flow & Metabolism, 1999
- NMR relaxation rates and blood oxygenation levelMagnetic Resonance in Medicine, 1995
- Functional Mapping of the Human Visual Cortex by Magnetic Resonance ImagingScience, 1991
- Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 TJournal of Magnetic Resonance Imaging, 1991
- Nuclear magnetic cross-relaxation spectroscopyJournal of Magnetic Resonance (1969), 1990
- Microgravimetric analysis of human brain tissue Correlation with computerized tomography scanningJournal of Neurosurgery, 1981
- The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit TimeStroke, 1974