Stair-Step Artifacts with Single versus Multiple Detector-Row Helical CT
- 1 July 2000
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 216 (1) , 185-196
- https://doi.org/10.1148/radiology.216.1.r00jn13185
Abstract
To compare the effects of acquisition parameters on the magnitude and appearance of artifacts between single and multiple detector-row helical computed tomography (CT). A cylindric (12.7 x 305.0-mm) acrylic rod inclined 45 degrees relative to the z axis was scanned at the isocenter and 100 mm from the isocenter with single detector-row (single-channel) helical CT (beam width, 1-10 mm; pitch, 1.0, 2.0, or 3.0) and multiple detector-row (four-channel) helical CT (detector width, 1. 25, 2.5, 3.75, and 5 mm; pitch, 0.75 or 1.5). The SD of radius measurements along the rod (SD(r)) was used to quantify artifacts in all 72 data sets and to analyze their frequency patterns. Volume-rendered images of the data sets were ranked by six independent and blinded readers; findings were correlated with acquisition parameters and SD(r) measurements. SD(r) was smaller in four- than in single-channel helical CT for any given table increment (TI). In single-channel helical CT, SD(r) increased linearly with beam width and geometrically with pitch. In four-channel helical CT, SD(r) measurements were directly proportional to the TI, regardless of the detector width and pitch combination used. Off-center object position on average increased SD(r) by a factor of 1.6 for single-channel helical CT and by a factor of 2.0 for four-channel helical CT. Subjective rankings of image quality correlated excellently with SD(r) (Spearman r = 0.94, P <.001). Artifacts are quantitatively and subjectively smaller with four- compared with single-channel helical CT for any given TI.Keywords
This publication has 12 references indexed in Scilit:
- Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT AngiographyRadiology, 2000
- Artefacts in spiral-CT images and their relation to pitch and subject morphologyEuropean Radiology, 1999
- Multi‐slice helical CT: Scan and reconstructionMedical Physics, 1999
- Longitudinal sampling and aliasing in spiral CTIEEE Transactions on Medical Imaging, 1999
- Automated flight path planning for virtual endoscopyMedical Physics, 1998
- Measurement of the aorta and its branches with helical CT.Radiology, 1998
- Nonstationary noise characteristics of the helical scan and its impact on image quality and artifactsMedical Physics, 1997
- Volumetric analysis of volumetric data: achieving a paradigm shift.Radiology, 1996
- Stair-step artifacts in three-dimensional helical CT: an experimental study.Radiology, 1994