Tracheal Intubation with the Macintosh Laryngoscope versus Intubating Laryngeal Mask Airway in Adults with Normal Airways
Open Access
- 1 June 2000
- journal article
- research article
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 28 (3) , 281-286
- https://doi.org/10.1177/0310057x0002800305
Abstract
We tested the hypothesis that haemodynamic changes to intubation and postoperative pharyngolaryngeal morbidity are similar for blind intubating laryngeal mask (ILM)-guided compared with laryngoscope-guided tracheal intubation in adults with normal airways. We also compared intubation success rates and airway complications. One-hundred and fifty paralysed, anaesthetized adult patients undergoing elective surgery were randomly assigned to one of three equal-sized groups: 1. blind intubation via the ILM using a straight, silicone tube; 2. intubation with a Macintosh laryngoscope using a straight silicone tube and 3. intubation with a Macintosh laryngoscope using a polyvinyl chloride tube (controls). A standard sequence of adjusting manoeuvres was followed if intubation was difficult. The number of adjusting manoeuvres and intubation attempts, time to intubation, intubation success rate (first attempt and within 3 min), haemodynamic changes (pre-induction, post-induction, post-intubation), oesophageal intubation, mucosal trauma (blood detected), hypoxia (SpO2 <95%) and postoperative pharyngolaryngeal morbidity (double-blinded) were documented. Time to successful intubation was longer (57 vs 35s), and more intubation attempts were required in the ILM group (P<0.0001). The intubation success rate was 100% (all first attempt) for the laryngoscope groups and 94% (56% first attempt) for the ILM group. There were no significant differences in heart rate or blood pressure among groups. Oesophageal intubation (26 v 0%) and mucosal trauma (19 v 2%) were more common in the ILM group. Hypoxia and postoperative pharyngolaryngeal morbidity were similar among groups. Blind intubation through the ILM offers no advantages over the Macintosh laryngoscope for adult patients requiring intubation for elective surgery with normal airways, but it is a feasible alternative.Keywords
This publication has 18 references indexed in Scilit:
- The Intubating Laryngeal Mask Airway With and Without Fiberoptic GuidanceAnesthesia & Analgesia, 1999
- Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patientsBritish Journal of Anaesthesia, 1999
- Erste Erfahrungen mit der IntubationslarynxmaskeDer Anaesthesist, 1998
- A Comparison of Light Wand and Suspension Laryngoscopic Intubation Techniques in OutpatientsAnesthesia & Analgesia, 1997
- Comparison of cardiovascular responses to airway management: Fiberoptic intubation using a new adapter, laryngeal mask insertion, or conventional laryngoscopic intubationJournal of Clinical Anesthesia, 1995
- Correlation of Endotracheal Tube Size with Sore Throat and Hoarseness Following General AnesthesiaAnesthesiology, 1987
- Difficult tracheal intubation: a retrospective studyAnaesthesia, 1987
- CARDIOVASCULAR AND CATECHOLAMINE RESPONSES TO LARYNGOSCOPY WITH AND WITHOUT TRACHEAL INTUBATIONBritish Journal of Anaesthesia, 1987
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984