A semi‐automatic technique for measurement of arterial wall from black blood MRI
- 12 June 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (6) , 1098-1107
- https://doi.org/10.1118/1.1368125
Abstract
Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semiautomatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple centers so as to increase access to real patient data without sacrificing reliability.Keywords
This publication has 21 references indexed in Scilit:
- Snakes, shapes, and gradient vector flowIEEE Transactions on Image Processing, 1998
- A methodology for evaluation of boundary detection algorithms on medical imagesIEEE Transactions on Medical Imaging, 1997
- Deformable models in medical image analysis: a surveyMedical Image Analysis, 1996
- The variability of manual and computer assisted quantification of multiple sclerosis lesion volumesMedical Physics, 1996
- Assessment of the reliability of the determination of carotid artery lumen sizes by quantitative image processing of magnetic resonance angiograms and imagesMagnetic Resonance Imaging, 1995
- Description of Complex Objects from Multiple Range Images Using an Inflating Balloon ModelComputer Vision and Image Understanding, 1995
- A discrete dynamic contour modelIEEE Transactions on Medical Imaging, 1995
- A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysisComputerized Medical Imaging and Graphics, 1995
- The pathogenesis of atherosclerosis: a perspective for the 1990sNature, 1993
- Finite-element methods for active contour models and balloons for 2-D and 3-D imagesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1993