Space plasma measurements with ion instruments
- 1 December 1989
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 60 (12) , 3750-3761
- https://doi.org/10.1063/1.1141075
Abstract
In this article we examine the factors which affect the determination of the plasma bulk parameters in space, with particular emphasis on the density determination. We make this assessment with reference to a particular instrument, the AMPTE‐UKS ion instrument, in order to be specific, but the issues raised here are likely to be encountered in the use of any space plasma instrument containing electrostatic energy analyzers or microchannel plate detectors. We have established a mathematical formalism for determining these parameters by relating the measured counts to the distribution function in terms of the geometric factor. The geometric factor is determined in the calibration of the instrument which is described in some detail. Among the factors we have considered are our calibration techniques, MCP efficiency, detector energy, and angular resolution, as well as the approximations used in our mathematical formalism. To establish confidence in our determination, we used a computer simulation to look for systematic errors in the particular characteristics of the analyzer and to verify the method of extraction of plasma parameters. We can conclude that the detector resolution is adequate for determining density for both solar wind (<5% error) and magnetosheath conditions (<6% error). The detector resolution is also adequate for measuring velocity, <1% error for the solar wind and <3% error in the magnetosheath. The detector resolution is not adequate for determining temperature in the solar wind ∼50%; however, in the magnetosheath where the thermal spread is at least as large as the acceptance angles, the resolution is adequate (<6%). In addition, we tested the influence of the geometric factor on the output bulk parameters by varying the input velocity direction over the entire polar range. The systematic error in the output parameters was less than 5% in all cases.Keywords
This publication has 8 references indexed in Scilit:
- On-board data analysis techniques for space plasma particle instrumentsReview of Scientific Instruments, 1989
- The magnetopause for large magnetic shear: AMPTE/IRM observationsJournal of Geophysical Research, 1986
- Determination of the detection efficiency of a channelplate electron multiplierReview of Scientific Instruments, 1986
- Performance of a microchannel plate ion detector in the energy range 3-25 keVJournal of Physics E: Scientific Instruments, 1985
- The AMPTE UKS Three-Dimensional Ion ExperimentIEEE Transactions on Geoscience and Remote Sensing, 1985
- A Space-Borne Plasma Analyser for Three-Dimensional Measurements of the Velocity DistributionIEEE Transactions on Nuclear Science, 1985
- Absolute and angular efficiencies of a microchannel-plate position-sensitive detectorReview of Scientific Instruments, 1984
- Graphical analysis method for a retarding potential analyzer and its application to the real-time measurements of ion temperature in space plasmasReview of Scientific Instruments, 1982