Heparin surface modified intraocular lenses
- 1 January 1992
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 18 (1) , 71-78
- https://doi.org/10.1016/s0886-3350(13)80386-0
Abstract
Two types of intraocular lenses (IOLs) were used in a controlled, randomized, double-masked clinical trial. The study lens was a one-piece, poly(methyl methacrylate) (PMMA) lens with heparin grafted on the entire surface. The control lens was identical in all respects but lacked the heparin surface. The IOLs were implanted in the capsular bag after extracapsular cataract extraction in 266 patients. No unexpected reactions or severe complications occurred. The postoperative visual acuity of all cases at the three-month visit was 20/40 or better in 91.6% of the heparin group and in 86.2% of the control group. When excluding cases with preoperative pathology, 97% of the heparin group and 95% of the control group had a visual acuity of 20/40 or better. A mild iritis was observed in one case of the heparin group and in four cases of the control group at three months. At three months there was a statistically significant difference between the heparin surface modified and control IOLs for both the number of patients with cellular precipitates and the number of precipitates per IOL. From the present data we conclude that during the first three postoperative months heparin surface modified lenses are more biocompatible than PMMA lenses.Keywords
This publication has 24 references indexed in Scilit:
- Intraocular PMMA lenses modified with surface-immobilized heparin: evaluation of biocompatibility in vitro and in vivoBiomaterials, 1989
- The Search for Thromboresistance Using Immobilized HeparinAnnals of the New York Academy of Sciences, 1987
- The Proteinaceous Coating and Cytology of Implant Lenses in RabbitsAmerican Journal of Ophthalmology, 1986
- Cytology of Human Intraocular LensesOphthalmic Research, 1986
- Morphology of pseudophakic precipitates on intraocular lenses removed from human patientsAmerican Intra-Ocular Implant Society Journal, 1985
- Biomicroscopy of Surface Deposits Resembling Foreign-Body Giant Cells on Implanted Intraocular LensesAmerican Journal of Ophthalmology, 1985
- Cytopathology of Intraocular Lens ImplantationOphthalmology, 1985
- Complications of intraocular lenses. A historical and histopathological reviewSurvey of Ophthalmology, 1984
- A New Non-Thrombogenic Surface Prepared by Selective Covalent Binding of Heparin Via a Modified Reducing Terminal ResidueBiomaterials, Medical Devices, and Artificial Organs, 1983
- Foreign body giant cells on intraocular lens implantsAlbrecht von Graefes Archiv für Ophthalmologie, 1982