Efficient Delivery to the Lungs of Flunisolide Aerosol From a New Portable Hand-Held Multidose Nebulizer
- 1 September 1996
- journal article
- clinical trial
- Published by American Geophysical Union (AGU) in Journal of Pharmaceutical Sciences
- Vol. 85 (9) , 960-964
- https://doi.org/10.1021/js950522q
Abstract
In order to provide asthmatic patients with an inhaler that does not use chlorofluorocarbon propellants, a novel multidose hand-held nebulizer (RESPIMAT, Boehringer Ingelheim Ltd.) has been developed. This device delivers 200 x 15 microL metered doses of drug solution, but does not use propellants of any kind. In this study of 10 healthy volunteers, the deposition pattern in the lungs and oropharynx of an ethanolic solution of flunisolide delivered via a prototype III multidose nebulizer has been determined by gamma scintigraphy. A comparison was made with the same dose (250 micrograms) of flunisolide delivered by a pressurized metered dose inhaler (MDI) and MDI plus Inhacort spacer. Mean (SD) whole lung deposition from the multidose nebulizer (39.7 (9.9) % of the metered dose) was significantly higher than that from either MDI (15.3 (5.1) %, P < 0.01) or MDI plus spacer (28.0 (7.0) %, P = 0.01). A mean 10.4% of the dose was recovered from an exhaled air filter for the multidose nebulizer, but less than 2% of the dose for MDI or MDI plus spacer. Oropharyngeal deposition was significantly reduced for the multidose nebulizer (39.9 (9.4) %) compared to MDI (66.9 (7.1) %), but was reduced further for the MDI plus spacer (27.3 (11.3) %). The multidose nebulizer delivers an unusually high percentage of an aerosol dose to the lungs, and it "targets" flunisolide to the lungs more effectively than the MDI. The multidose nebulizer could constitute a viable alternative to MDIs in asthma maintenance therapy.Keywords
This publication has 20 references indexed in Scilit:
- Effect of Add-on Devices for Aerosol Drug Delivery: Deposition Studies and Clinical AspectsJournal of Aerosol Medicine, 1996
- An in vitro evaluation of various spacer devices for metered-dose inhalers using the Twin ImpingerInternational Journal of Pharmaceutics, 1994
- Total and regional lung deposition of terbutaline sulphate inhaled via a pressurised MDI or via Turbuhaler®International Journal of Pharmaceutics, 1993
- Effect of vapour pressure on the deposition pattern from solution phase metered dose inhalersInternational Journal of Pharmaceutics, 1993
- Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug.Thorax, 1993
- Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airflow obstruction.Thorax, 1993
- Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.Thorax, 1991
- Delivery of propellant soluble drug from a metered dose inhaler.Thorax, 1991
- Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids?Thorax, 1990
- Effect of extension devices on the drug deposition from inhalation aerosolsInternational Journal of Pharmaceutics, 1987