The effect of blood perfusion rate on the temperature distributions induced by multiple, scanned and focused ultrasonic beams in dogs' kidneysin vivo
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 5 (4) , 485-497
- https://doi.org/10.3109/02656738909140473
Abstract
The effect of blood perfusion rate on the temperature distribution during scanned, focused ultrasound hyperthermia was investigated using an in vivo dog kidney model. The results showed that the ultrasound beams could penetrate through the body wall without severe distortion, and that they could be used to induce controlled temperature elevations in the target volume. The blood perfusion rate of the heated tissue significantly modified the temperature distribution and the temperatures achieved in the kidney with no flow were about five times higher than in the case with full flow for the same applied acoustic power. It was also demonstrated that the power deposition pattern produced by scanned focused ultrasonic fields could be modified to give an acceptable temperature distribution in different perfusion situations. Similar trends were also obtained by using the bioheat transfer equation to simulate the experiment. Both the magnitude of the temperature elevations and the effect of perfusion on the temperature distributions obtained in the experiments were in agreement with the simulations. The main difference occurred at high perfusion rates where the experiments showed significant temperature elevation outside of the scanned volume and the simulation results predicted hardly any temperature increase 5 mm outside the scan. These observations indicate that both the theoretical power calculation programme and the temperature simulations will have value in the design of optimal heating systems, treatment planning and in the retrospective evaluation of the achieved temperature distributions.Keywords
This publication has 15 references indexed in Scilit:
- A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatmentsInternational Journal of Hyperthermia, 1987
- The Effect of Scanning Speed on Temperature and Equivalent Thermal Exposure Distributions During Ultrasound Hyperthermia In VivoIEEE Transactions on Microwave Theory and Techniques, 1986
- Tumor Blood Flow-Characterization, Modifications, and Role in HyperthermiaIEEE Transactions on Sonics and Ultrasonics, 1984
- Local hyperthermia induced by focussed and overlapping ultrasonic fields—An in vivo demonstrationUltrasound in Medicine & Biology, 1983
- Design of thermistor probes for measurement of ultrasound intensity distributionsUltrasonics, 1983
- Nonlinear Acoustic Behavior in Focused Ultrasonic Fields: Observations of Intensity Dependent Absorption in Biological TissueIEEE Transactions on Sonics and Ultrasonics, 1981
- The Focussing of Ultrasound Beams Through Human TissuePublished by Springer Nature ,1980
- Ultrasonic absorption and attenuation in mammalian tissuesUltrasound in Medicine & Biology, 1979
- Comprehensive compilation of empirical ultrasonic properties of mammalian tissuesThe Journal of the Acoustical Society of America, 1978
- INTENSE FOCUSED ULTRASOUND: Its Production, Effects and UtilizationPublished by Elsevier ,1978