Simultaneous MEG and EEG source analysis
- 5 June 2001
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (7) , 1737-1751
- https://doi.org/10.1088/0031-9155/46/7/301
Abstract
A method is described to derive source and conductivity estimates in a simultaneous MEG and EEG source analysis. In addition the covariance matrix of the estimates is derived. Simulation studies with a concentric spheres model and a more realistic boundary element model indicate that this method has several advantages, even if only a few EEG sensors are added to a MEG configuration. First, a simultaneous analysis profits from the 'preferred' location directions of MEG and EEG. Second, deep sources can be estimated quite accurately, which is an advantage compared to MEG. Third, superficial sources profit from accurate MEG location and from accurate EEG moment. Fourth, the radial source component can be estimated, which is an advantage compared to MEG. Fifth, the conductivities can be estimated. It is shown that conductivity estimation gives a substantial increase in precision, even if the conductivities are not identified appropriately. An illustrative analysis of empirical data supports these findings.Keywords
This publication has 25 references indexed in Scilit:
- Regional head tissue conductivity estimation for improved EEG analysisIEEE Transactions on Biomedical Engineering, 2000
- Localisation of epileptic foci with electric, magnetic and combined electromagnetic modelsElectroencephalography and Clinical Neurophysiology, 1998
- Localization of spatial attention processes with the aid of a probe techniqueElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1998
- A Bayesian approach to introducing anatomo-functional priors in the EEG/MEG inverse problemIEEE Transactions on Biomedical Engineering, 1997
- A consensus statement on relative merits of EEG and MEGElectroencephalography and Clinical Neurophysiology, 1992
- Automated Fitting of Nonstandard ModelsMultivariate Behavioral Research, 1992
- A random dipole model for spontaneous brain activityIEEE Transactions on Biomedical Engineering, 1992
- Demonstration of useful differences between magnetoencephalogram and electroencephalogramElectroencephalography and Clinical Neurophysiology, 1983
- Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp ThicknessesIEEE Transactions on Biomedical Engineering, 1981
- Comparison of the magnetoencephalogram and electroencephalogramElectroencephalography and Clinical Neurophysiology, 1979