Rapid Flow of Passive Neutrophils Into a 4 μm Pipet and Measurement of Cytoplasmic Viscosity
- 1 August 1990
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 112 (3) , 269-276
- https://doi.org/10.1115/1.2891184
Abstract
Neutrophils from five different individuals are isolated with a density separation technique. A total of 151 unactivated (passive) cells are rapidly aspirated at constant suction pressure and at room temperature into a pipet with a diameter of 4 μm. The suction pressures in excess of an initial yield threshold are 0.5, 1 and 2 kPa and are comparable to those encountered in the microcirculation. These pressures are well in excess of the small suction pressure of ~ 20 Pa that is required to form a static hemispherical bump on the cell. At a given aspiration pressure, the leading edge of an individual cell is “tracked” as it flows into the pipet. A theory based on the flow of a Newtonian liquid from either a hemisphere or a spherical segment into a cylinder is used to model the entry process. Both theory and experiment show that during most of the entry process the leading edge of the cell moves at a nearly constant velocity with a rapid acceleration at the end. For cells from five different individuals at the three different excess aspiration pressures, Newtonian theory gives a cytoplasmic viscosity of 135 ± 54 Pa·s and overall entry times of 3.3s (0.5 kPa), 1.6s (1 kPa) and 0.82s (2 kPa). These results and those of Evans and Yeung at lower aspiration pressures indicate that the complex cytoplasm inside unactivated neutrophils behaves as a nearly Newtonian fluid with a viscosity on the order of 102 Pa·s over almost a two order of magnitude range in aspiration pressure and, thus, rate of deformation.Keywords
This publication has 11 references indexed in Scilit:
- Rapid deformation of “passive” polymorphonuclear leukocytes: The effects of pentoxifyllineJournal of Cellular Physiology, 1989
- The Application of a Homogeneous Half-Space Model in the Analysis of Endothelial Cell Micropipette MeasurementsJournal of Biomechanical Engineering, 1988
- Passive Deformation Analysis of Human LeukocytesJournal of Biomechanical Engineering, 1988
- Magnetic particle motions within living cells. Measurement of cytoplasmic viscosity and motile activityBiophysical Journal, 1987
- F-actin and Microtubule Suspensions as Indeterminate FluidsScience, 1987
- PASSIVE MATERIAL BEHAVIOR OF GRANULOCYTES BASED ON LARGE DEFORMATION AND RECOVERY AFTER DEFORMATION TESTS1984
- Passive mechanical properties of human leukocytesBiophysical Journal, 1981
- Changes in plasma-membrane-associated filaments during endocytosis and exocytosis in polymorphonuclear leukocytesCell, 1981
- MORPHOMETRY OF HUMAN-LEUKOCYTES1980
- Changing patterns of plasma membrane-associated filaments during the initial phases of polymorphonuclear leukocyte adherence.The Journal of cell biology, 1979