Relation Between Air-Filled Albumin Microbubble and Red Blood Cell Rheology in the Human Myocardium
- 1 August 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 94 (3) , 445-451
- https://doi.org/10.1161/01.cir.94.3.445
Abstract
Background We have previously shown that the intravascular rheology of sonicated air-filled albumin microbubbles is similar to that of red blood cells (RBCs) and that their myocardial transit rate is also similar to that of RBCs in the beating canine heart. In the present study, we tested the hypothesis that the myocardial transit rates of these microbubbles reflect those of RBCs in humans at different coronary flow rates. Methods and Results RBC and microbubble transit rates were measured in 17 patients undergoing coronary angiography: in 8, measurements were made only at rest, whereas in 9, they were performed both at rest and during a pacing-induced increase in coronary blood flow. A γ-variate function was used to derive mean RBC and microbubble transit rates from the time-activity and time-intensity plots after the left main injection of RBCs and microbubbles, respectively. There was linear correlation between the myocardial transit rates with both tracers with the slope of the correlation determined by the specific echocardiographic system that was used. Microbubble transit rate consistently overestimated RBC transit rate due to artificial narrowing of the time-intensity curves caused by chest wall attenuation of the echocardiographic signal, which was confirmed through in vitro experiments. Conclusions There is close correlation between air-filled albumin microbubbles and RBC rheology in the human myocardium. The use of these microbubbles in the cardiac catheterization laboratory could, therefore, provide further insights into myocardial blood flow/myocardial blood volume relations in humans.Keywords
This publication has 16 references indexed in Scilit:
- Intravenous perfluoropropane-exposed sonicated dextrose albumin produces myocardial ultrasound contrast that correlates with coronary blood flowJournal of the American Society of Echocardiography, 1995
- Technical factors that influence the determination of microbubble transit rate during contrast echocardiographyJournal of the American Society of Echocardiography, 1995
- Intracoronary air-filled albumin microspheres for myocardial blood flow measurementJournal of the American College of Cardiology, 1993
- Flow quantitation by contrast echocardiographyThe International Journal of Cardiovascular Imaging, 1993
- An Association between Collateral Blood Flow and Myocardial Viability in Patients with Recent Myocardial InfarctionNew England Journal of Medicine, 1992
- Intravascular ultrasound and intracardiac echocardiography: Concepts for the futureThe American Journal of Cardiology, 1992
- A look at 15 years of planar thallium-201 imagingAmerican Heart Journal, 1989
- Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiographyJournal of the American College of Cardiology, 1989
- RBC velocity profiles in arterioles and venules of the rabbit omentumMicrovascular Research, 1975
- Ratio of red cell velocities near the vessel wall to velocities at the vessel center in cerebral microcirculation, and an apparent effect of blood viscosity on this ratioMicrovascular Research, 1972