Radiographic analysis of a low-modulus titanium-alloy femoral total hip component. Two to six-year follow-up.
- 1 January 1985
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 67 (1) , 48-56
- https://doi.org/10.2106/00004623-198567010-00007
Abstract
We performed a detailed serial radiographic analysis of the femoral component of 323 cemented low-modulus titanium-alloy total hip prostheses. There was a low incidence of femoral component loosening as manifested by radiolucent zones at the stem-cement interface or cement fractures. There was also a low incidence of resorption of the calcar and cortical hypertrophy. Comparison of our data with those of others indicated that the incidence of loosening, calcar resorption, and cortical hypertrophy was usually lower than with similarly designed conventional high-modulus Charnley stems. These findings appear to support computer-modeling studies that have predicted a more even distribution of stresses along the entire length of the stem of the titanium-alloy prosthesis. Of the two configurations of femoral components used, the straight stems demonstrated a significantly lower incidence of radiographic evidence of loosening, calcar resorption, and cortical hypertrophy than the curved stems did. These findings have provided sufficient biomechanical rationale for the evolutionary development of the second-generation femoral components, which incorporate many features of the straight stem.This publication has 9 references indexed in Scilit:
- The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component.Journal of Bone and Joint Surgery, 1984
- Localized Bone Resorption in the Femur in Mechanical Failure of Cemented Total Hip ArthroplastiesActa Orthopaedica, 1983
- Femoral component loosening using contemporary techniques of femoral cement fixation.Journal of Bone and Joint Surgery, 1982
- Ten-year follow-up study of total hip replacement.Journal of Bone and Joint Surgery, 1982
- The effect of calcar contact on femoral component micromovement. A mechanical study.Journal of Bone and Joint Surgery, 1980
- The influence of design parameters on calcar stresses following femoral head arthroplastyJournal of Biomedical Materials Research, 1980
- An analysis of femoral component stem design in total hip arthroplasty.Journal of Bone and Joint Surgery, 1980
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components.Journal of Bone and Joint Surgery, 1978