Capillary Electrochromatography and Capillary Electrochromatography−Mass Spectrometry for the Analysis of DNA Adduct Mixtures
- 1 February 1997
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (3) , 379-384
- https://doi.org/10.1021/ac9606968
Abstract
Capillary electrochromatography (CEC) is an emerging technique that can be applied to the separation of neutral compound mixtures and provides a versatile alternative to micellar electrokinetic chromatography. In this paper, CEC is applied to the separation of polycyclic aromatic hydrocarbons (PAHs) and in vitro reaction products of PAH deoxynucleoside adducts. Some unique features related to CEC, such as convenience of stopping the flow, nanoliter flow rate, and low sample consumption, are discussed. On-column focusing in CEC can be conducted by introducing the analytes in a solution of lower solvent strength followed by elution with a stronger mobile phase, in a manner analogous to that used in normal HPLC (e.g., a 10-fold preconcentration factor can be readily achieved). Coupling of CEC to mass spectrometry for the detection of a relatively dilute DNA adduct mixture solution (10-6 M) using the on-column focusing method is also presented.Keywords
This publication has 18 references indexed in Scilit:
- Capillary electrochromatography: operating characteristics and enantiomeric separationsJournal of Chromatography A, 1996
- Detection and Identification of Benzo[a]pyrene Diol Epoxide Adducts to DNA Utilizing Capillary Electrophoresis-Electrospray Mass SpectrometryAnalytical Chemistry, 1996
- Determination of in Vitro Formed DNA Adducts of 2-Amino-1-methyl-6-phenylimidazo[4,5-b]pyridine Using Capillary Liquid Chromatography/Electrospray Ionization/Tandem Mass SpectrometryChemical Research in Toxicology, 1995
- Characterization of DNA Adducts Formed by anti-Benzo[g]chrysene 11,12-Dihydrodiol 13,14-EpoxideChemical Research in Toxicology, 1995
- Evaluation of the parameters determining the performance of electrochromatography in packed capillary columnsJournal of Chromatography A, 1995
- Capillary Electrochromatography-Electrospray Mass Spectrometry: A Microanalysis TechniqueAnalytical Chemistry, 1995
- Reaction with DNA and Mutagenic Specificity of syn-Benzo[g]chrysene 11,12-Dihydrodiol 13,14-EpoxideChemical Research in Toxicology, 1994
- Tandem mass spectrometry of peptides using hybrid and four-sector instruments: A comparative studyAnalytical Chemistry, 1991
- High-resolution separations based on electrophoresis and electroosmosisJournal of Chromatography A, 1981
- Electro-osmosisJournal of Chromatography A, 1974