Myocardial Infarction as a Presentation of Clinical In-Stent Restenosis
Open Access
- 1 January 2006
- journal article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 70 (8) , 1026-1029
- https://doi.org/10.1253/circj.70.1026
Abstract
Background In-stent restenosis is considered to be a gradual and progressive condition and there is scant data on myocardial infarction (MI) as a clinical presentation. Methods and Results Of 2,462 consecutive patients who underwent percutaneous coronary intervention between June 2001 and December 2002, clinical in-stent restenosis occurred in 212 (8.6%), who were classified into 3 groups: ST elevation MI (STEMI), non-ST elevation MI (NSTEMI) and non-MI. Of the 212 patients presenting with clinical in-stent restenosis, 22 (10.4%) had MI (creatine kinase (CK) ≥2 × baseline with elevated CKMB). The remaining 190 (89.6%) patients had stable angina or evidence of ischemia by stress test without elevation of cardiac enzymes. Median interval between previous intervention and presentation for clinical in-stent restenosis was shorter for patients with MI than for non-MI patients (STEMI, 90 days; NSTEMI, 79 days; non-MI, 125 days; p=0.07). Diffuse in-stent restenosis was more frequent in MI patients than in non-MI patients (72.7% vs 56.3%; p<0.005). Renal failure was more prevalent in patients with MI than in those without MI (31.8% vs 6.3%, p=0.001). Compared with the non-MI group, patients with MI were more likely to have acute coronary syndromes at the time of index procedure (81.8% vs 56.8%, p=0.02). Conclusion Clinical in-stent restenosis can frequently present as MI and such patients are more likely to have an aggressive angiographic pattern of restenosis. Renal failure and acute coronary syndromes at the initial procedure are associated with MI. (Circ J 2006; 70: 1026 - 1029)Keywords
This publication has 25 references indexed in Scilit:
- Angiographic Patterns of In-Stent RestenosisCirculation, 1999
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Restenosis after coronary angioplasty: A multilvariate statistical model to relate lesion and procedure variables to restenosisJournal of the American College of Cardiology, 1991
- Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery StentNew England Journal of Medicine, 1991
- Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.Circulation, 1991
- Restenosis After Successful Percutaneous Transluminal Coronary Angioplasty: Serial Angiographic Follow-Up of 229 PatientsJournal of the American College of Cardiology, 1988
- Clinical and angiographic assessment 6 months after double vessel percutaneous coronary angioplastyJournal of the American College of Cardiology, 1985
- Restenosis after percutaneous transluminal coronary angioplasty (PTCA): A report from the PTCA registry of the national heart, lung, and blood instituteThe American Journal of Cardiology, 1984
- Long-term efficacy of percutaneous transluminal coronary angioplasty (PTCA): Report from the national heart, lung, and blood institute PTCA registryThe American Journal of Cardiology, 1984