Micromachined hydraulic astable multivibrator
- 29 January 1995
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Abstract
The paper presents a hydraulic astable multivibrator system. The system consists of hydraulic resistors, hydraulic capacitors and hydraulic pressure controlled valves. The system is designed, realised and tested. The measured system behaviour agrees well with the model simulations. The free running frequency of the multivibrator is 0.18 Hz and the output pressure swing is 90% of the supply pressureKeywords
This publication has 1 reference indexed in Scilit:
- Integrated micro-liquid dosing systemPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002