Determination of macro-constituents in advanced ceramic materials by inductively coupled plasma atomic emission spectrometry
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 7 (6) , 869-875
- https://doi.org/10.1039/ja9920700869
Abstract
An analytical method was developed for the determination of macro-constituents by inductively coupled plasma atomic emission spectrometry in the following six advanced ceramic materials: calcia partially stabilized zirconia (Ca-PSZ), yttria–ceria–tetragonal zirconia polycrystalline (Y-TZP/Ce), barium titanate (BaTiO3), gadolinium-modified lead titanate (Gd-PT), lead zirconate–titanate (PZT) and lanthanum-modified lead zirconate–titanate (PLZT). The dissolution of the samples was achieved by using the following methods: decomposition with HCl in a poly(tetrafluoroethylene)(PTFE)-lined pressure vessel at 160 °C for 16 h; decomposition with HF + H2SO4 in a PTFE-lined pressure vessel at 170 °C for 16 h; decomposition with (NH4)2SO4+ H2SO4 in a glass beaker; decomposition with (NH4)2SO4+ H2SO4 in a platinum dish; fusion with Na2CO3+ Na2B4O7 in a platinum crucible; and fusion with Li2B4O7 in a graphite crucible. The precision of the determination of the macro-constituents with regard to the wavelength, integration time, dilution of the sample solution and use of an internal standard was studied. In general, the highest precision was obtained by employing the most sensible analytical line of each element, by working with elevated integration times (700–1000 ms), by diluting the sample solution 1 + 9 or 1 + 19 and by using V or Y as an internal standard. The analytical results obtained following three different methods of dissolution for each advanced ceramic material were in excellent agreement. Good precision and accuracy were attained; the relative standard deviations for the results obtained for each element for each dissolution method are <1%.Keywords
This publication has 21 references indexed in Scilit:
- Applications of nuclear analytical techniques in environmental research. Plenary lectureThe Analyst, 1992
- Effect of Excess PbO on the Densification of PLZT CeramicsJournal of the American Ceramic Society, 1989
- Surface analysis with the glow discharge lamp. State of the art and prospects for future developmentJournal of Analytical Atomic Spectrometry, 1988
- Preparation and stoichiometry effects on microstructure and properties of high purity BaTio3Ferroelectrics, 1987
- Piezoelectric ceramicsMaterials Chemistry and Physics, 1986
- Solubility of BaO in BaTiO3Journal of the American Ceramic Society, 1985
- Role and behaviour of orthotitanate Ba2TiO4 during the processing of BaTiO3 based ferroelectric ceramicsJournal of Materials Science, 1984
- Simultaneous determination of major, minor, and trace elements in marine sediments by inductively coupled plasma atomic emission spectrometryAnalytical Chemistry, 1981
- Effect of PbO Deficiency on the Piezoelectric Properties of Lead Zirconate‐Titanate CeramicsJournal of the American Ceramic Society, 1967
- A Microstructure Study of Barium Titanate CeramicsJournal of the American Ceramic Society, 1956