Abstract
Between‐sample variation in high‐throughput flow cytometry data poses a significant challenge for analysis of large‐scale data sets, such as those derived from multicenter clinical trials. It is often hard to match biologically relevant cell populations across samples because of technical variation in sample acquisition and instrumentation differences. Thus, normalization of data is a critical step before analysis, particularly in large‐scale data sets from clinical trials, where group‐specific differences may be subtle and patient‐to‐patient variation common. We have developed two normalization methods that remove technical between‐sample variation by aligning prominent features (landmarks) in the raw data on a per‐channel basis. These algorithms were tested on two independent flow cytometry data sets by comparing manually gated data, either individually for each sample or using static gating templates, before and after normalization. Our results show a marked improvement in the overlap between manual and static gating when the data are normalized, thereby facilitating the use of automated analyses on large flow cytometry data sets. Such automated analyses are essential for high‐throughput flow cytometry. © 2009 International Society for Advancement of CytometryKeywords
This publication has 14 references indexed in Scilit:
- Automated high-dimensional flow cytometric data analysisProceedings of the National Academy of Sciences, 2009
- flowClust: a Bioconductor package for automated gating of flow cytometry dataBMC Bioinformatics, 2009
- flowCore: a Bioconductor package for high throughput flow cytometryBMC Bioinformatics, 2009
- Toward automation of flow data analysisCytometry Part A, 2008
- Feature significance for multivariate kernel density estimationComputational Statistics & Data Analysis, 2008
- Automated gating of flow cytometry data via robust model‐based clusteringCytometry Part A, 2008
- Quality Control in Clinical Flow CytometryClinics In Laboratory Medicine, 2007
- Mean fluorescence intensity rate is a useful marker in the detection of paroxysmal nocturnal hemoglobinuria clonescclm, 2005
- Estimating Smooth Monotone FunctionsJournal of the Royal Statistical Society Series B: Statistical Methodology, 1998
- Curve RegistrationJournal of the Royal Statistical Society Series B: Statistical Methodology, 1998