BIS Monitoring to Prevent Awareness during General Anesthesia
- 1 March 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 94 (3) , 520-522
- https://doi.org/10.1097/00000542-200103000-00025
Abstract
Background: Unexpected awareness is a rare but well-described complication of general anesthesia that has received increased scientific and media attention in the past few years. Transformed electroencephalogram monitors, such as the Bispectral Index monitor, have been advocated as tools to prevent unexpected recall. Methods: The authors conducted a power analysis to estimate how many patients would be needed in an appropriately powered study to demonstrate the Bispectral Index monitor reduces awareness, as well as a cost analysis to assess the cost of using the monitor for this purpose alone. Results: If unexpected recall is rare (1 in 20,000), it will require a large study to demonstrate that the monitor reduces awareness (200,000-800,000 patients), and the cost of using it for this purpose alone would be high ($400,000 per case prevented). If awareness is common (1 in 100), then the number of patients needed in a study to demonstrate that the monitor works becomes tractable (1,000-4,000 patients), and the cost of using the monitor for this purpose alone becomes lower ($2,000 per case prevented). Because there are reported cases of awareness despite Bispectral Index monitoring, the authors are certain that the effectiveness of the monitor is less than 100%. As the performance of the monitor decreases from 100%, the size of the study needed to demonstrate that it works increases, as does the cost of using it to prevent awareness. Conclusion: The contention that Bispectral Index monitoring reduces the risk of awareness is unproven, and the cost of using it for this indication is currently unknown.Keywords
This publication has 17 references indexed in Scilit:
- Preoperative intensive care unit admission and hemodynamic monitoring in patients scheduled for major elective noncardiac surgery: A retrospective review of 95 patientsJournal of Cardiothoracic and Vascular Anesthesia, 1998
- Bispectral Index Monitoring Allows Faster Emergence and Improved Recovery from Propofol, Alfentanil, and Nitrous Oxide AnesthesiaAnesthesiology, 1997
- Bispectral Analysis Measures Sedation and Memory Effects of Propofol, Midazolam, Isoflurane, and Alfentanil in Healthy VolunteersAnesthesiology, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Perception and memory during general anaesthesiaBritish Journal of Anaesthesia, 1994
- Insufficient AnaesthesiaBMJ, 1950
- THE USE OF CURARE IN INFANTS AND CHILDRENAnesthesiology, 1947
- THE LACK OF CEREBRAL EFFECTS OF d -TUBOCUARINEAnesthesiology, 1947
- TUBOCURARINE CHLORIDE AS AN ADJUNCT TO ANESTHESIA REPORT ON 180 CASESThe Lancet, 1946
- CLINICAL OBSERVATIONS ON THE USE OF CURARE IN ANESTHESIAAnesthesiology, 1945