Performance of Adult Ineraid and Nucleus Cochlear Implant Patients after 3.5 Years of Use
- 1 January 1995
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 34 (3) , 135-144
- https://doi.org/10.3109/00206099509071907
Abstract
Forty-two postlingually deafened adult patients, 21 with a formant extraction version of the Nucleus cochlear implant and 21 with the Ineraid cochlear implant (analog processing), were evaluated on a series of speech perception tests after using their implants for about 3.5 years. A wide range of performance was observed across patients for both devices. All but 4 patients showed an enhancement in their lipreading ability with the implant. Word recognition averaged about 14–19% correct, and word recognition in sentences averaged about 43–49% correct for the two implant groups. Average performance was superior with the Ineraid implant on consonant recognition in noise. An information transmission analysis suggested that vowel perception was influenced by first- and third-for-mant frequency for the Nucleus, and first-formant and fundamental frequency for the Ineraid patients. It appeared that the Ineraid device was more effective, on average, at conveying information about consonant nasality and frication. For consonant perception, nasality and frication contributed most to the total information transmitted for both implant types. Both devices had difficulty conveying information about vowel second-formant frequency and consonant place information. These scores at 3.5 years are substantially elevated from preoperative performance and, overall, the patients clearly benefit from their implant.Keywords
This publication has 18 references indexed in Scilit:
- An Experimental Comparison of Cochlear Implant SystemsSeminars in Hearing, 1992
- Comparison of Speech Recognition Ability with Different Speech Processing Strategies by Korean Cochlear ImplanteesAnnals of Otology, Rhinology & Laryngology, 1992
- Performance over Time with a Nucleus or Ineraid Cochlear ImplantEar & Hearing, 1992
- Natural Vowel Perception by Patients with the Ineraid Cochlear ImplantInternational Journal of Audiology, 1992
- Performance of Postlinguistically Deaf Adults with the Wearable Speech Processor (WSP III) and Mini Speech Processor (MSP) of the Nucleus Multi-Electrode Cochlear Implant*Ear & Hearing, 1991
- Evaluation of five different cochlear implant designs: Audiologic assessment and predictors of performanceThe Laryngoscope, 1988
- Speech discrimination in deaf subjects with cochlear implantsThe Journal of the Acoustical Society of America, 1980
- Speech-Discrimination Scores Modeled as a Binomial VariableJournal of Speech and Hearing Research, 1978
- AN EXPANDED TEST FOR SPEECH DISCRIMINATION UTILIZING CNC MONOSYLLABIC WORDS: NORTHWESTERN UNIVERSITY AUDITORY TEST NO. 6Published by Defense Technical Information Center (DTIC) ,1966
- An Analysis of Perceptual Confusions Among Some English ConsonantsThe Journal of the Acoustical Society of America, 1955