New quantitative three-dimensional echocardiographic indices of mitral valve stenosis
- 22 February 2007
- journal article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 23 (6) , 707-716
- https://doi.org/10.1007/s10554-007-9211-2
Abstract
We studied the value of quantitative three-dimensional echocardiography (3DE) in the evaluation of mitral valve stenosis using the measurement of the mitral valve area (MVA) with two new indices: the doming volume and mitral valve volume. A total of 45 consecutive patients with mitral valve stenosis were studied. MVA was measured using Doppler with the pressure half-time (PHT) method. Following a diagnostic multiplane transesophageal (TEE) examination, data for 3DE were acquired with a rotational mode of acquisition. MVA was assessed by anyplane echocardiography (APE) and from surface rendered images. Moreover, the doming volume, i.e., the volume subtended by the anterior and posterior mitral valve and annular cut plane was measured by APE. Comparing PHT-derived with 3DE-derived MVA’s, using both APE and surface rendered images, only moderate correlations were observed: PHT-derived MVA versus APE-derived MVA: r = 0.74, P < 0.0001; PHT-derived area versus 3DE-surface rendered MVA: r = 0.70, P < 0.0001. Multiple linear regression analysis showed a relation of atrial fibrillation to the doming volume (P = 0.04), but not to PHT-derived MVA (P = 0.28), APE-derived area (P = 0.33) and mitral valve volume (P = 0.08). Comparison of patients with MVA < 1 cm2 and MVA > 1 cm2 revealed significant difference in mitral valve volume: mean mitral valve volume in critical stenosis was 3.7 ml versus 1.4 ml in non-critical stenosis (P = 0.04). Only moderate correlations between 3DE and Doppler-derived MVA’s were observed. Measurement of the doming volume allows quantification of the 3DE geometry of the mitral apparatus. Patients with conical or funnel-like geometry are more likely to have sinus rhythm, whereas, patients with flat geometry are likely to have atrial fibrillation. Mitral valve volume can be used for the evaluation of mitral stenosis severity. These new 3DE indices might be used for selection of patients for balloon valvuloplasty.Keywords
This publication has 31 references indexed in Scilit:
- Usefulness of Three-Dimensionally Guided Assessment of Mitral Stenosis Using Matrix-Array UltrasoundThe American Journal of Cardiology, 2005
- Comparison of Accuracy of Mitral Valve Area in Mitral Stenosis by Real-Time, Three-Dimensional Echocardiography Versus Two-Dimensional Echocardiography Versus Doppler Pressure Half-TimeThe American Journal of Cardiology, 2005
- Additional value of three-dimensional transesophageal echocardiography for patients with mitral valve stenosis undergoing balloon valvuloplastyJournal of the American Society of Echocardiography, 2003
- Accurate assessment of mitral valve area in patients with mitral stenosis by three-dimensional echocardiographyJournal of the American Society of Echocardiography, 1997
- Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiographyThe International Journal of Cardiovascular Imaging, 1996
- Aortic regurgitation shortens Doppler pressure half-time in mitral stenosis: Clinical evidence, in vitro simulation and theoretic analysisJournal of the American College of Cardiology, 1990
- Influence of orifice geometry and flow rate on effective valve area: An in vitro studyJournal of the American College of Cardiology, 1990
- Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation.Heart, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound.Circulation, 1979