Long-Term Followup After Mobile-Bearing Total Knee Replacement
- 1 November 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 404 (404) , 40-50
- https://doi.org/10.1097/00003086-200211000-00008
Abstract
Clinical, radiographic, lanalyses and survivorship were done on the initial cementless series of 309 posterior cruciate-retaining meniscal-bearing and rotating-platform New Jersey LCS® total knee replacements followed up for 10 to 20 years (mean, 12.4 years). Clinical results in patients surviving at least 10 years using a strict knee scoring scale were similar for posterior cruciate ligament-retaining and posterior cruciate ligament-sacrificing designs. Good to excellent results were seen in 97.9% of primary posterior cruciate-retaining-bearing prostheses and in 97.9% of primary rotating-platform prostheses. Radiographic analysis of minimum 10-year followup radiographs showed generally stable fixation of all components with gross migration seen in one tibial component (0.6%) in a patient with a failed high tibial osteotomy. Significant osteolysis was present requiring bearing exchange and bone grating in three patients with cementless rotating-platform prostheses (1.8%) who had multiple knee surgeries at an average of 10.2 years from the index surgery. Survivorship of the primary cementless posterior cruciate-retaining meniscal-bearing prostheses with an end point of revision for any mechanical reason was 97.4% at 10 years and 83% at 16 years; using an end point of a poor clinical knee score, the survivorship was 98.9% at 10 and 16 years, respectively. Survivorship of the primary cementless rotating-platform prostheses with end points of revision for any mechanical reason or a poor clinical knee score was 98.3% survivorship at 10 and 18 years, respectively. In the current study, no cementless rotating-bearing patella loosened, fractured, or dissociated in patients without prior knee surgery although one cementless rotating-bearing patella (0.6%) in a patient who had multiple knee surgeries wore through the inferior marker wire after 10.8 years, causing metallosis that required revision.Keywords
This publication has 10 references indexed in Scilit:
- Mobile-Bearing Knee ReplacementJournal of Bone and Joint Surgery, 2000
- The AGC total knee prosthesis at average 11 yearsThe Journal of Arthroplasty, 2000
- Cemented Rotating-Platform Total Knee ReplacementJournal of Bone and Joint Surgery, 2000
- Results and complications of the low contact stress knee prosthesisThe Journal of Arthroplasty, 1999
- The results at ten years of the Insall-Burstein II total knee replacementThe Journal of Bone and Joint Surgery. British volume, 1999
- Survivorship Analysis of Cementless Meniscal Bearing Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1997
- The Rotating Platform Mobile Bearing TKAOrthopedics, 1996
- Evaluation of Contact Stress in Metal-Backed Patellar ReplacementsPublished by Wolters Kluwer Health ,1991
- The Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring SystemClinical Orthopaedics and Related Research, 1989
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958