Rapid MR Imaging of Articular Cartilage with Steady-State Free Precession and Multipoint Fat-Water Separation
- 1 February 2003
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (2) , 357-362
- https://doi.org/10.2214/ajr.180.2.1800357
Abstract
OBJECTIVE. To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat—water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS. The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat—water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS. High-quality images of the knee with excellent fat—water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION. High-quality high-resolution images of articular cartilage with improved fat—water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat—water separation technique.Keywords
This publication has 19 references indexed in Scilit:
- Cartilage Substitutes: Overview of Basic Science and Treatment OptionsJournal of the American Academy of Orthopaedic Surgeons, 2001
- Treatable Chondral Injuries in the KneeAmerican Journal of Roentgenology, 2000
- MR imaging of articular cartilage.Radiology, 1998
- Water‐fat imaging with direct phase encodingJournal of Magnetic Resonance Imaging, 1997
- An extended two‐point dixon algorithm for calculating separate water, fat, and B0 imagesMagnetic Resonance in Medicine, 1997
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- Epidemiological Aspects of OsteoarthritisScandinavian Journal of Rheumatology, 1988
- Steady-State Magnetizations in Rapid NMR Imaging Using Small Flip Angles and Short Repetition IntervalsIEEE Transactions on Medical Imaging, 1987
- Transverse coherence in rapid FLASH NMR imagingJournal of Magnetic Resonance (1969), 1987
- Simple proton spectroscopic imaging.Radiology, 1984