Determination of diquat and paraquat in water by liquid chromatography-(electrospray ionization) mass spectrometry
- 1 August 1998
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 9 (8) , 830-839
- https://doi.org/10.1016/s1044-0305(98)00043-9
Abstract
A method for the determination of the herbicides diquat and paraquat in water was developed using liquid chromatography-(electrospray ionization) mass spectrometry [LC-(ESI)MS]. The analytes were isolated on an ENVI-8 DSK solid phase extraction (SPE) disk and eluted with 5-M trifluoroacetic acid (TFA). The eluate was evaporated to dryness and the analytes were redissolved in the mobile phase (7% methanol/93% water/25-mM TFA). The extract was analyzed by liquid chromatography (C1 column) with postcolumn addition of propionic acid/methanol followed by (ESI)MS. Diquat was detected using the [M(2+)-H+] ion (M2+ = dication) at m/z 183, whereas paraquat was detected using the mono-trifluoroacetate ion pair [M2 +/- OOCCF3] at m/z 299. Quantitation was done by isotope dilution mass spectrometry using d4-diquat and d8-paraquat and the corresponding ions [M(2+)-D+] and [M2 +/- OOCCF3] at m/z 186 and m/z 307, respectively. Detection limits of 0.1 and 0.2 microgram/L, respectively (based on the dications), were adequate to meet the Ontario Drinking Water Objectives of 70 and 10 micrograms/L, respectively, and the Ontario Provincial Water Quality Objective for diquat of 0.5 microgram/L. Precision and accuracy were 14% and 6% for diquat and 12% and 3% for paraquat.Keywords
This publication has 19 references indexed in Scilit:
- On-line liquid chromatographic trace enrichment and high-performance liquid chromatographic determination of diquat, paraquat and difenzoquat in waterJournal of Chromatography A, 1996
- Determination of diquat and paraquat in water using high-performance liquid chromatography with confirmation by liquid chromatography-particle beam mass spectrometryJournal of Chromatography A, 1994
- Determination of quaternary amine pesticides by thermospray mass spectrometryJournal of Chromatography A, 1993
- Analysis of paralytic shellfish poisoning toxins by automated pre-column oxidation and microcolumn liquid chromatography with fluorescence detectionJournal of Chromatography A, 1993
- Determination of paraquat and diquat by liquid chromatography-thermospray mass spectrometryJournal of Chromatography A, 1993
- Rapid determination of paraquat in urine with ion-pair extraction and spectrophotometryBulletin of Environmental Contamination and Toxicology, 1990
- Purification of anti-paraquat monoclonal antibodies by affinity chromatography on immobilised haptenJournal of Chromatography A, 1990
- Determination of diquat by a photokinetic methodThe Analyst, 1990
- Gas chromatographic determination of diquat and paraquat in cropsJournal of Chromatography A, 1989
- Use of FAB MS/MS for analysis of quarternary amine pesticide standardsJournal of Mass Spectrometry, 1987