Maxon und PDS ? Bewertung physikalischer und biologischer Eigenschaften monofiler, absorbierbarer Nahtmaterialien
- 1 March 1987
- journal article
- conference paper
- Published by Springer Nature in Langenbecks Archives Of Surgery
- Vol. 371 (1) , 13-28
- https://doi.org/10.1007/bf01259240
Abstract
The physical parameters of monofilament absorbable suture (Maxon and PDS) were studied. Compared to PDS Maxon proved somewhat more unwieldy, however, it required less complicated knot combinations for a secure placement than PDS did. In vivo experiments on rats showed a slight tissue reaction and a dissolution time of 120–180 days for Maxon and 180–240 days for PDS. With Maxon, tensile strength was measurable for 42–49 days, while the period for PDS amounted to 65–80 days. New indications for these materials are discussed, two parameters, easy knot formation and atraumatic passage through the tissue, especially favor the use of Maxon for one-row all-layer sutures in the gastrointestinal tract. Monofile, absorbierbare Nahtmaterialien (Maxon and PDS) wurden in physikalischen Grundgrößen untersucht. Im Handling erwies sich Maxon etwas sperriger als PDS, benötigt aber einfachere Knotenkombinationen als PDS bis zum sicheren Knotensitz. In vivo Versuche an Ratten zeigen eine schwachgradige Gewebereaktion und eine Auflösungszeit von 120–180 Tagen bei Maxon und 180–240 Tagen bei PDS. Maxon weist für 42–49 Tage, PDS für 65–80 Tage meßbare Zugfestigkeit auf. Neue Indikationen für diese Materialien werden erörtert. Insbesondere die Anwendung von Maxon im Gastrointestinaltrakt bei einreihigen, allschichtigen Nähten wird durch die guten vorteilhaften Parameter Knotenfunktion und atraumatisches Gewebedurchzugsverhalten gefördert.This publication has 17 references indexed in Scilit:
- Repair of Growing VesselsArchives of Surgery, 1985
- COMPARISON BETWEEN ABSORBABLE AND NONABSORBABLE, MONOFILAMENT SUTURES FOR END-TO-END ARTERIAL ANASTOMOSES IN GROWING-PIGS1984
- Standardisierung der Nachweisverfahren zur Objektivierung der linearen Fadenzug-, Knotenbruch-und Knotensitzfestigkeit verschiedener absorbierbarer und nichtabsorbierbarer NahtmaterialienPublished by Springer Nature ,1982
- Mechanical performance of polyglycolic acid and polyglactin 910 synthetic absorbable sutures.1981
- An in‐vitro study of the effect of buffer on the degradation of poly(glycolic acid) suturesJournal of Biomedical Materials Research, 1981
- Mechanical performance of sutures in surgeryThe American Journal of Surgery, 1977
- Physical Properties of Surgical Suture MaterialsAnnals of Surgery, 1976
- Mechanical performance of surgical suturesThe American Journal of Surgery, 1975
- Changes in Tensile Strength and Knot Security of Surgical Sutures in VivoArchives of Surgery, 1973
- Nylon Bands for Closure of Median Sternotomy Incisions: An Unacceptable MethodThe Annals of Thoracic Surgery, 1972