Late implant infections caused by Propionibacterium acnes in scoliosis surgery
- 20 April 2005
- journal article
- Published by Springer Nature in European Spine Journal
- Vol. 14 (8) , 783-788
- https://doi.org/10.1007/s00586-004-0854-6
Abstract
One hundred and one consecutive adolescent scoliosis patients instrumented from the posterior between 1995 and 2002, with a minimum follow-up of 24 months (maximum 106 months), were reviewed for incidence of infection. Stainless steel implants with pedicle screws were used in the thoracic and lumbar spine of all patients. All were operated on by a single surgeon. There were no early infections. Incidence of late infection was 6.9% (seven patients). Clinical indicators for infection were the sudden onset of local pain and swelling without fever after an initial pain-free interval. There were no reliable laboratory parameters. Normal CRP and ESR did not rule out a late infection. Extended cultures were done from intraoperative swabs. Propionibacterium acnes was found in six patients. There were no other organisms identified. No causative organism could be identified in one patient, despite extended cultures. All patients were successfully treated with implant removal and antibiotic therapy for 4–9 weeks. No pseudarthrosis was seen on implant removal. Despite bony fusion, loss of correction between 10° and 26° was observed in three patients after implant removal.Keywords
This publication has 32 references indexed in Scilit:
- Adhesion of Staphylococcus to orthopaedic metals, an in vivo studyJournal of Orthopaedic Research, 2004
- Late Infection in Patients With Scoliosis Treated With Spinal InstrumentationClinical Orthopaedics and Related Research, 2003
- Delayed Infections After Posterior TSRH Spinal Instrumentation for Idiopathic ScoliosisSpine, 2001
- Late Operative Site Pain With Isola Posterior Instrumentation Requiring Implant RemovalSpine, 2001
- Deep Wound Infections After Neuromuscular Scoliosis SurgerySpine, 2000
- Reoperation After Primary Posterior Instrumentation and Fusion for Idiopathic ScoliosisSpine, 2000
- Delayed Infection After Elective Spinal Instrumentation and FusionSpine, 1997
- Infection adjacent to titanium and bone cement implants: an experimental study in rabbitsBiomaterials, 1995
- Late Infection of Spinal Instrumentation by Hematogenous SeedingSpine, 1993
- In vitro and in vivo comparative colonization of Staphylococcus aureus and Staphylococcus epidermidis on orthopaedic implant materialsBiomaterials, 1989