Left Ventricular Performance Indices by Transesophageal Doppler
Open Access
- 1 November 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 69 (5) , 728-737
- https://doi.org/10.1097/00000542-198811000-00015
Abstract
The purpose of this study was to assess whether blood flow velocity signals, obtained by esophageal continuous-wave Doppler, reflect changes in ventricular performance. Ventricular performance has previously been determined by analysis of blood flow velocity signals sampled in the ascending aorta. In this investigation velocity signals were acquired from the descending aorta, with the use of an esophageal Doppler transducer. Maximum blood flow velocity (Vm), maximum blood flow volume acceleration (Acclv), and maximum blood linear flow acceleration (Acc) were the velocity signals used to evaluate left ventricular performance. Twenty-six patients scheduled for myocardial revascularization and anesthetized with fentanyl (50 .mu.g/kg) and pancuronium (0.15 mg/kg) were studied. In seven patients (Group I) a good correlation (r = 0.91) was observed between Accv, in the ascending and descending aorta. In 10 patients (Group 2), halothane (0.5 and 1.0 MAC end-tidal) was added to the anesthetic. At these halothane concentrations Vm, Accv, and Acc measured in the descending aorta remained unchanged. Decreases were noted in the product of mean arterial pressure (MAP) and Acc (P-Acc; decreased 20% at 0.5 MAC and 39% at 1 MAC) and the product of systemic vascular resistance and Acc (R-Acc; decreased 25% at 1 MAC). In nine patients (Group 3), phenylephrine was used to reverse the decrease in MAP induced by 1 MAC halothane. Under these conditions, Vm, Acc, Accv, and P-Acc showed similar decreases (.apprx. 80% of baseline values), whereas R-Acc returned to the baseline values. In summary, indices of blood flow in the descending aorta were easily determined with a commercial transesophageal continuous-wave Doppler device. Descending and ascending aortic blood flow Accv correlated well, and the changes in the product of MAP and Acc in the descending aorta reflected the anticipated, halothane-induced, changes in left ventricular performance. In conclusion, descending aortic blood flow acceleration contains information on left ventricular performance that can be derived by the minimally invasive transesophagealDoppler technique.Keywords
This publication has 10 references indexed in Scilit:
- Comparative influence of load versus inotropic states on indexes of ventricular contractility: experimental and theoretical analysis based on pressure-volume relationships.Circulation, 1987
- Evaluation of left ventricular function during upright exercise: correlation of exercise Doppler with postexercise two-dimensional echocardiographic results.Circulation, 1987
- Continuous Noninvasive Monitoring of Cardiac Output with Esophageal Doppler Ultrasound during Cardiac SurgeryAnesthesia & Analgesia, 1986
- Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous-wave Doppler velocity meter.Circulation, 1986
- Impaired left ventricular function in acute myocardial infarction assessed by Doppler measurement of ascending aortic blood velocity and maximum accelerationThe American Journal of Cardiology, 1986
- The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac outputAmerican Heart Journal, 1985
- Ascending aortic blood velocity and acceleration using Doppler ultrasound in the assessment of left ventricular functionCardiovascular Research, 1984
- The use of Doppler flow velocity measurement to assess the hemodynamic response to vasodilators in patients with heart failure.Circulation, 1983
- Left Ventricular Function in Conscious Man and during Halothane AnesthesiaAnesthesiology, 1978
- Left Ventricular Ejection in Conscious Dogs:Circulation Research, 1966