Temporary Intravenous Bag Silo Closure in Severe Abdominal Trauma
- 1 February 1996
- journal article
- research article
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 40 (2) , 258-260
- https://doi.org/10.1097/00005373-199602000-00014
Abstract
Several temporary abdominal wall closure techniques have been described in the literature. We present our experience with an inexpensive and efficient method of temporary abdominal closure when bowel edema and distension preclude safe primary closure. Our technique is a variation of the silon (silo) closure used in the repair of gastroschisis and omphalocele, using a pre-gas-sterilized, soft 3-L plastic cystoscopy fluid irrigation bag cut to an oval shape and stapled or sutured to the skin edges of the wound.Keywords
This publication has 17 references indexed in Scilit:
- The Staged Celiotomy for Trauma Issues in Unpacking and ReconstructionAnnals of Surgery, 1993
- Abbreviated Laparotomy and Planned Reoperation for Critically Injured PatientsAnnals of Surgery, 1992
- Alternative Approaches to Abdominal Wound Closure in Severely Injured Patients with Massive Visceral EdemaPublished by Wolters Kluwer Health ,1992
- Packing and Planned Reexploration for Hepatic and Retroperitoneal Hemorrhage: Critical Refinements of a Useful TechniquePublished by Wolters Kluwer Health ,1990
- Abdominal Gunshot WoundsAnnals of Surgery, 1988
- The Measurement of Intra-abdominal Pressure as a Criterion for Abdominal Re-explorationAnnals of Surgery, 1984
- Management of the Major Coagulopathy with Onset during LaparotomyAnnals of Surgery, 1983
- Elevated Intra-abdominal Pressure and Renal FunctionAnnals of Surgery, 1982
- Hemodynamic and respiratory alterations with increased intra-abdominal pressureJournal of Surgical Research, 1976
- THE EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON RENAL FUNCTION IN MAN 1Journal of Clinical Investigation, 1947