High spatial resolution measurements of organ blood flow in small laboratory animals
- 1 November 2000
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 279 (5) , H2043-H2052
- https://doi.org/10.1152/ajpheart.2000.279.5.h2043
Abstract
With the use of a newly developed Imaging Cryomicrotome to determine the spatial location of fluorescent microspheres in organs, we validate and report our processing algorithms for measuring regional blood flow in small laboratory animals. Microspheres (15-μm diameter) of four different fluorescent colors and one radioactive label were simultaneously injected into the left ventricle of a pig. The heart and kidneys were dissected, and the numbers of fluorescent and radioactive microspheres were determined in 10 randomly selected pieces. All microsphere counts fell well within the 95% expected confidence limits as determined from the radioactive counts. Fluorescent microspheres (15-μm diameter) of four different colors were also injected into the tail vein of a rat and the left ventricle of a rabbit. After correction for Poisson noise, correlation coefficients between the colors were 0.99 ± 0.02 (means ± SD) for the rabbit heart and 0.99 ± 0.02 for the rat lung. Mathematical dissection algorithms, statistics to analyze the spatial data, and methods to visualize blood flow distributions in small animal organs are presented.Keywords
This publication has 25 references indexed in Scilit:
- Regional blood flow measurements from fluorescent microsphere images using an Imaging CryoMicrotomeReview of Scientific Instruments, 2000
- Pulmonary Blood Flow Distribution in SheepAnesthesiology, 1997
- Both gravity and non‐gravity dependent factors determine regional blood flow within the goat lungActa Physiologica Scandinavica, 1995
- Distribution of pulmonary blood flow in conscious resting ratsRespiration Physiology, 1994
- Evidence for long-term fluctuations in regional blood flow within the rabbit left ventricleActa Physiologica Scandinavica, 1992
- Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging.Circulation, 1992
- Measurement of regional myocardial blood flow with multiple colored microspheres.Circulation, 1991
- An Algorithm for Finding Best Matches in Logarithmic Expected TimeACM Transactions on Mathematical Software, 1977
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977
- Uniform Random Number GeneratorsJournal of the ACM, 1965