Artifact and noise suppression in GRAPPA imaging using improved k‐space coil calibration and variable density sampling
Open Access
- 22 December 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (1) , 186-193
- https://doi.org/10.1002/mrm.20328
Abstract
A parallel imaging technique, GRAPPA (GeneRalized Auto-calibrating Partially Parallel Acquisitions), has been used to improve temporal or spatial resolution. Coil calibration in GRAPPA is performed in central k-space by fitting a target signal using its adjacent signals. Missing signals in outer k-space are reconstructed. However, coil calibration operates with signals that exhibit large amplitude variation while reconstruction is performed using signals with small amplitude variation. Different signal variations in coil calibration and reconstruction may result in residual image artifact and noise. The purpose of this work was to improve GRAPPA coil calibration and variable density (VD) sampling for suppressing residual artifact and noise. The proposed coil calibration was performed in local k-space along both the phase and frequency encoding directions. Outer k-space was acquired with two different reduction factors. Phantom data were reconstructed by both the conventional GRAPPA and the improved technique for comparison at an acceleration of two. Under the same acceleration, optimal sampling and calibration parameters were determined. An in vivo image was reconstructed in the same way using the predetermined optimal parameters. The performance of GRAPPA was improved by the localized coil calibration and VD sampling scheme. Magn Reson Med 53:186–193, 2005.Keywords
This publication has 14 references indexed in Scilit:
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Self‐calibrating parallel imaging with automatic coil sensitivity extractionMagnetic Resonance in Medicine, 2002
- 2D sense for faster 3D MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2002
- Generalized SMASH imagingMagnetic Resonance in Medicine, 2001
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Coil‐by‐coil image reconstruction with SMASHMagnetic Resonance in Medicine, 2001
- A generalized approach to parallel magnetic resonance imagingMedical Physics, 2001
- Tailored SMASH image reconstructions for robust in vivo parallel MR imagingMagnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997