A unified analysis of exact methods of inverting the 2-D exponential radon transform, with implications for noise control in SPECT
- 1 January 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (4) , 643-658
- https://doi.org/10.1109/42.476106
Abstract
Exact methods of inverting the two-dimensional (2-D) exponential Radon transform have been proposed by Bellini et al. (1979) and by Inouye et al. (1989), both of whom worked in the spatial-frequency domain to estimate the 2-D Fourier transform of the unattenuated sinogram; by Hawkins et al. (1988), who worked with circularly harmonic Bessel transforms; and by Tretiak and Metz (1980), who followed filtering of appropriately-modified projections by exponentially-weighted backprojection. With perfect sampling, all four of these methods are exact in the absence of projection-data noise, but empirical studies have shown that they propagate noise differently, and no underlying theoretical relationship among the methods has been evident. Here, an analysis of the 2-D Fourier transform of the modified sinogram reveals that all previously-proposed linear methods can be interpreted as special cases of a broad class of methods, and that each method in the class can be implemented, in principle, by any one of four distinct techniques. Moreover, the analysis suggests a new member of the class that Is predicted to have noise properties better than those of previously-proposed members.Keywords
This publication has 9 references indexed in Scilit:
- Noise properties of attenuation correction methods for SPECTPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- Implementation and evaluation of an analytical solution to the photon attenuation and nonstationary resolution reconstruction problem in SPECTPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Simultaneous correction of attenuation and distance-dependent resolution in SPECT: an analytical approachPhysics in Medicine & Biology, 1993
- Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuationPhysics in Medicine & Biology, 1989
- The circular harmonic transform for SPECT reconstruction and boundary conditions on the Fourier transform of the sinogramIEEE Transactions on Medical Imaging, 1988
- Fourier Inversion of the Attenuated X-Ray TransformSIAM Journal on Mathematical Analysis, 1984
- The Use of Filtering Methods to Compensate for Constant Attenuation in Single-Photon Emission Computed TomographyIEEE Transactions on Biomedical Engineering, 1981
- The Exponential Radon TransformSIAM Journal on Applied Mathematics, 1980
- Compensation of tissue absorption in emission tomographyIEEE Transactions on Acoustics, Speech, and Signal Processing, 1979