Fiber Optic Sensing of Fluorescent Emission from Compressed Cyanine-Dye-Impregnated Fatty Acid Monolayers at the Air/Water Interface
- 1 May 1988
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 42 (4) , 605-608
- https://doi.org/10.1366/0003702884429292
Abstract
Fluorescence was collected from cyanine-dye-impregnated arachidic acid monolayers at the air/water interface with the use of a fiber optics configuration and a Langmuir film balance. Fatty-acid-to-dye molar ratios in the monolayers ranged from 99:1 to 1:1. The monolayers were compressed in a step-wise manner, with sampling of cyanine fluorescence after each compression step. A drop in fluorescence intensity ranging from 20 to 80% was observed between the uncompressed and compressed monolayers. The observed fluorescence decrease appeared to be a function of barrier pressure rather than molecular area and dye concentration.Keywords
This publication has 7 references indexed in Scilit:
- Demonstration of Reciprocity in the Angular Pattern of Fluorescence Emission Collected from Langmuir-Blodgett Deposited Thin FilmsApplied Spectroscopy, 1988
- Emission Spectroscopy Utilizing an Air-Cooled Argon Laser and an Optrode-Based UV-Vis Spectrophotometer: A Scaled-Down Laser Spectroscopy Configuration for Solution-Phase Fiber Optic SensingApplied Spectroscopy, 1987
- Analytical chemistry with optical sensorsAnalytical and Bioanalytical Chemistry, 1986
- Principles of Fluorescence SpectroscopyPublished by Springer Nature ,1983
- Selectivity of fluorescent lipid analogs for lipid domainsBiochemistry, 1980
- Utilization of Optical Fibers in Remote Inelastic Light Scattering ProbesPublished by Springer Nature ,1979
- Chemiluminescence fiber optic probe for hydrogen peroxide based on the luminol reactionAnalytical Chemistry, 1978