A device for the determination of the microsecond component of the in vivo chlorophyll fluorescence induction kinetics
- 1 June 1990
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 1 (6) , 517-521
- https://doi.org/10.1088/0957-0233/1/6/010
Abstract
A device for the measurement of the in vivo chlorophyll fluorescence induction kinetics at the wavelengths 685 nm and 730 nm is described. The excitation light provided by a He-Ne laser is switched by an acousto-optic modulator (Bragg cell) which achieves a rise time of the excitation light intensity Ie of 0.3 mu s. A combination with an additional mechanical shutter ensures that Ie is constant within 11% during the total measuring time of 5 min. Data acquisition is accomplished by a transient recorder with a time resolution of 10 mu s and a computer with a sampling rate adjusted between 5000 s-1 and 5 s-1. The initial fluorescence intensity F0, the inflection point Ip (during the rise of the fluorescence at the beginning), the maximum intensity Fp and the final steady-state value Fs can be evaluated with high accuracy, so additional information is provided to estimate the efficiency of the photosynthetic system.Keywords
This publication has 14 references indexed in Scilit:
- The Role of Chlorophyll Fluorescence in The Detection of Stress Conditions in PlantsC R C Critical Reviews in Analytical Chemistry, 1988
- Simultane Messung der Chlorophyll Fluoreszenz‐Kinetik bei verschiedenen Wellenlángen als rasches Verfahren zur Frühdiagnose von Immissionsbelastungen an Waldbäumen: Ozoneinwirkungen auf Buchen und PappelnEuropean Journal of Forest Pathology, 1987
- Application of chlorophyll fluorescence in ecophysiologyRadiation and Environmental Biophysics, 1986
- Determination of leaf heat resistance: comparative investigation of chlorophyll fluorescence changes and tissue necrosis methodsOecologia, 1984
- Chlorophyll fluorescence as a tool in plant physiologyPhotosynthesis Research, 1984
- Chlorophyll fluorescence yield changes as a tool in plant physiology I. The measuring systemPhotosynthesis Research, 1983
- Chlorophyll a fluorescence transients: a fast data acquisition system to facilitate in vivo measurementsPhotosynthesis Research, 1983
- Analysis of the slow phases of the in vivo chlorophyll fluorescence induction curve. Changes in the redox state of Photosystem II electron acceptors and fluorescence emission from Photosystems I and IIBiochimica et Biophysica Acta (BBA) - Bioenergetics, 1981
- Photosynthetic activity, chloroplast ultrastructure, and leaf characteristics of high-light and low-light plants and of sun and shade leavesPhotosynthesis Research, 1981
- Chlorophyll Fluorescence Assay for Ozone Injury in Intact PlantsPlant Physiology, 1978