Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical Evaluation
Top Cited Papers
- 1 October 2005
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 237 (1) , 213-223
- https://doi.org/10.1148/radiol.2363041220
Abstract
To prospectively compare dose reduction and image quality achieved with an automatic exposure control system that is based on both angular (x-y axis) and z-axis tube current modulation with dose reduction and image quality achieved with an angular modulation system for multi-detector row computed tomography (CT). The study protocol was approved by the institutional review board, and oral informed consent was obtained. In two groups of 200 patients, five anatomic regions (ie, the thorax, abdomen-pelvis, abdomen-liver, lumbar spine, and cervical spine) were examined with this modulation system and a six-section multi-detector row CT scanner. Data from these patients were compared with data from 200 patients who were examined with an angular modulation system. Dose reduction by means of reduction of the mean effective tube current in 600 examinations, image noise in 200 examinations performed with each modulation system, and subjective image quality scores in 100 examinations per-formed with each modulation system were compared with Wilcoxon signed rank tests. Mean dose reduction for the angular and z-axis tube current modulation system and for the angular modulation system was as follows: thorax, 20% and 14%, respectively; abdomen-liver, 38% and 18%, respectively; abdomen-pelvis, 32% and 26%, respectively; lumbar spine, 37% and 10%, respectively; and cervical spine, 68% and 16%, respectively. These differences were statistically significant (P < .05). There was no significant difference in image noise and mean image quality scores between modulation systems, with the exception of cervical spinal examinations (P < .001 for both), where the examinations with angular modulation resulted in better scores. There is good correlation between the mean effective tube current level and the body mass index of patients with the new modulation system. Correlation was as follows: thorax, 0.77; abdomen-pelvis, 0.83; abdomen-liver, 0.84; lumbar spine, 0.8; and cervical spine, 0.6. This correlation was not observed with the angular modulation system. An automatic exposure control mechanism that is based on real-time anatomy-dependent tube current modulation delivers good image quality with a significantly reduced radiation dose.Keywords
This publication has 22 references indexed in Scilit:
- Estimated Radiation Risks Potentially Associated with Full-Body CT ScreeningRadiology, 2004
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countriesThe Lancet, 2004
- National Conference on Dose Reduction in CT, with an Emphasis on Pediatric PatientsAmerican Journal of Roentgenology, 2003
- CT and Computed Radiography: The Pictures Are Great, But Is the Radiation Dose Greater Than Required?American Journal of Roentgenology, 2002
- The ALARA Concept in Pediatric CT: Myth or Reality?Radiology, 2002
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- Managing patient dose in computed tomographyAnnals of the ICRP, 2000
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999