Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation
- 25 July 2003
- journal article
- Published by Wiley in Medical Physics
- Vol. 30 (8) , 2206-2217
- https://doi.org/10.1118/1.1587411
Abstract
Common clinical brachytherapy treatment planning algorithms perform at best one-dimensional corrections for high Z heterogeneities that will be inaccurate for intermediate energies (60-100 keV). The development of fast methods for a three-dimensional dose calculation to account for high Z materials in this energy range is important, e.g., to fully utilize the potential of patient individualized shields using isotopes such as 241Am and 169Yb. In this work we use the collapsed cone superposition algorithm to calculate the scatter dose contribution around partly lead-shielded point sources at 60, 100, and 350 keV. Methods to scale point kernels for water into kernels for high Z materials are derived. The scaling accounts for scattered photon spectral differences between materials and thus goes beyond the common density scaling approach. Compared to Monte Carlo simulations, the results of our algorithm yield agreements on the unshielded side to within 3% at 350 and 60 keV and to within 7% at 100 keV out to distances of 8 cm from the source. The effect of the shield in the center of the unshielded region is small at 350 keV but significant and occurs at short distances at 100 and 60 keV. At 60 keV, the shield causes a dose reduction of around 10%, 1 cm from the source on the unshielded side. At 100 keV, the reverse effect is seen, the insertion of shields leading to the total dose being increased by about 10% at 1 cm. That one-dimensional algorithms are incapable of predicting these changes shows the importance of accounting for the full three-dimensional geometry in correctly determining the scatter dose contribution.Keywords
This publication has 37 references indexed in Scilit:
- Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shieldsMedical Physics, 1996
- Dose calculation in brachytherapy for a source using a primary and scatter dose separation techniquePhysics in Medicine & Biology, 1996
- Monte Carlo modeling of coherent scattering: influence of interferenceIEEE Transactions on Nuclear Science, 1996
- Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new ytterbium-169 brachytherapy sourceInternational Journal of Radiation Oncology*Biology*Physics, 1994
- A convolution algorithm for brachytherapy dose computations in heterogeneous geometriesMedical Physics, 1991
- A dose computation model for 241Am vaginal applicators including the source‐to‐source shielding effectsMedical Physics, 1990
- Dose calculation and measurements for a CT compatible version of the fletcher applicatorInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Development of an 24Am applicator for intracavitary irradiation of gynecologic cancersInternational Journal of Radiation Oncology*Biology*Physics, 1988
- Buildup factors and dose around a 1 3 7 Cs source in the presence of inhomogeneitiesMedical Physics, 1983
- Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100Atomic Data and Nuclear Data Tables, 1970