Human K10 epithelial keratin is the most abundant protein in airborne dust of both occupied and unoccupied school rooms
- 9 November 2007
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 10 (1) , 55-59
- https://doi.org/10.1039/b714802j
Abstract
Previously it was demonstrated that the levels of large particles (>2 micron) and associated bacterial cell envelope markers increase greatly on occupation in schools; it was hypothesized that the source of both was shed human skin. In the current work to test this hypothesis, room air cleaners were used to collect airborne dust (>50–100 mg) from occupied and unoccupied school rooms which was then subjected to proteomic analysis. Proteins were extracted from the dust and separated using two dimensional gel electrophoresis (2D GE). In situdigestion of protein spots with trypsin released peptides, which were subsequently analyzed by matrix assisted laser desorption/deionization, time-of-flight mass spectrometry (MALDI-TOF-MS) and tandem mass spectrometry (MALDI-TOF-MS-MS). In Coomassie blue stained gels, a single spot generally dominated the 2D gels; this protein was identified by tandem mass spectrometry as K10 epithelial keratin. The results experimentally confirm previous anecdotal reports that human skin is readily shed into air and suggest that increased levels of microbial markers and large particles observed in occupied rooms are also derived from skin.Keywords
This publication has 24 references indexed in Scilit:
- Strain-resolved community proteomics reveals recombining genomes of acidophilic bacteriaNature, 2007
- High-throughput fluorescent multiplex array for indoor allergen exposure assessmentJournal of Allergy and Clinical Immunology, 2006
- Rapid identification and strain-typing of respiratory pathogens for epidemic surveillanceProceedings of the National Academy of Sciences, 2005
- Large particles are responsible for elevated bacterial marker levels in school air upon occupationPublished by Royal Society of Chemistry (RSC) ,2005
- Increased levels of bacterial markers and CO2 in occupied school roomsJournal of Environmental Monitoring, 2003
- Investigation of the Concentration of Bacteria and Their Cell Envelope Components in Indoor Air in Two Elementary SchoolsJournal of the Air & Waste Management Association, 2000
- Spread of coagulase-negative staphylococci during cardiac operations in a modern operating roomThe Annals of Thoracic Surgery, 2000
- Dust‐borne bacteria in animal sheds, schools and children's day care centresJournal of Applied Microbiology, 1999
- Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometryNature, 1996
- Bioaerosol and particle mass levels and ventilation in finnish homesEnvironment International, 1989