Computer-aided method for quantification of cartilage thickness and volume changes using mri: validation study using a synthetic model
- 22 July 2003
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 50 (8) , 978-988
- https://doi.org/10.1109/tbme.2003.814539
Abstract
The primary objective of this study was to develop a computer-aided method for the quantification of three-dimensional (3-D) cartilage changes over time in knees with osteoarthritis (OA). We introduced a local coordinate system (LCS) for the femoral and tibial cartilage boundaries that provides a standardized representation of cartilage geometry, thickness, and volume. The LCS can be registered in different data sets from the same patient so that results can be directly compared. Cartilage boundaries are segmented from 3-D magnetic resonance (MR) slices with a semi-automated method and transformed into offset-maps , defined by the LCS. Volumes and thickness are computed from these offset-maps. Further anatomical labeling allows focal volumes to be evaluated in predefined subregions. The accuracy of the automated behavior of the method was assessed, without any human intervention, using realistic, synthetic 3-D MR images of a human knee. The error in thickness evaluation is lower than 0.12 mm for the tibia and femur. Cartilage volumes in anatomical subregions show a coefficient of variation ranging from 0.11% to 0.32%. This method improves noninvasive 3-D analysis of cartilage thickness and volume and is well suited for in vivo follow-up clinical studies of OA knees.Keywords
This publication has 12 references indexed in Scilit:
- Determination of 3D cartilage thickness data from MR imaging: Computational method and reproducibility in the livingMagnetic Resonance in Medicine, 1999
- MRI simulation-based evaluation of image-processing and classification methodsIEEE Transactions on Medical Imaging, 1999
- Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurementsOsteoarthritis and Cartilage, 1999
- Accuracy of Cartilage Volume and Thickness Measurements With Magnetic Resonance ImagingPublished by Wolters Kluwer Health ,1998
- Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images.Radiology, 1996
- The rician distribution of noisy mri dataMagnetic Resonance in Medicine, 1995
- Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.Annals of the Rheumatic Diseases, 1995
- Computing the modulation transfer function of a magnetic resonance imagerMedical Physics, 1994
- On Detecting EdgesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1986
- The Laplacian Pyramid as a Compact Image CodeIEEE Transactions on Communications, 1983