A Comparison of Lung Deposition Patterns Between Different Asthma Inhalers
- 1 September 1995
- journal article
- research article
- Published by Mary Ann Liebert Inc in Journal of Aerosol Medicine
- Vol. 8 (s3) , S21-21
- https://doi.org/10.1089/jam.1995.8.suppl_3.s-21
Abstract
Drugs for the treatment and prophylaxis of asthma are delivered to the lungs by inhalation and this is facilitated by the use of pressurized metered dose inhalers (pMDIs), pMDIs with spacer devices and dry powder inhalers (DPIs). Lung deposition of drugs from pMDIs depends upon both the physicochemical nature of the aerosol formulation and the patient's inhalation technique, however, the majority of the dose from a pMDI is deposited in the oropharynx. Large volume spacer devices can reduce oropharyngeal deposition; however, lung deposition may be increased or decreased with a spacer in comparison with a pMDI, according to the design of the spacer, the aerosol formulation, the patient's inhalation technique and the extent to which the electrostatic charge on the spacer is controlled. Lung deposition of drug from DPIs also varies according to the design of the device. One DPI, Turbuhaler®, deposits twice as much drug in the lungs as a pMDI, has a lower intersubject variability of lung deposition and results in lower oropharyngeal deposition.Keywords
This publication has 9 references indexed in Scilit:
- Dose emissions from marketed dry powder inhalersInternational Journal of Pharmaceutics, 1995
- Lung deposition of budesonide from Turbuhaler is twice that from a pressurized metered-dose inhaler P-MDIEuropean Respiratory Journal, 1994
- Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjectsEuropean Respiratory Journal, 1994
- Total and regional lung deposition of terbutaline sulphate inhaled via a pressurised MDI or via Turbuhaler®International Journal of Pharmaceutics, 1993
- Bronchodilator Delivery From Gentlehaler, a New Low-Velocity Pressurized Aerosol InhalerChest, 1993
- Gamma scintigraphy in the evaluation of pharmaceutical dosage formsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1992
- Lung deposition of 5 mg Intal from a pressurised metered dose inhaler assessed by radiotracer techniqueInternational Journal of Pharmaceutics, 1991
- Pressurised aerosol deposition in the human lung with and without an "open" spacer device.Thorax, 1989
- Effect of powder inhaler design on drug deposition in the respiratory tractInternational Journal of Pharmaceutics, 1988