Multiview Active Appearance Models for Simultaneous Segmentation of Cardiac 2- and 4-Chamber Long-Axis Magnetic Resonance Images
- 1 April 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (4) , 195-203
- https://doi.org/10.1097/01.rli.0000154216.94316.f7
Abstract
Rationale and Objectives: Long-axis cardiac magnetic resonance (MR) views enable a rapid, online evaluation of cardiac function from only 2 views. In this article, we aimed to evaluate a model-based method for the simultaneous detection of 2- and 4-chamber endocardial and epicardial contours in end-diastolic and end-systolic phases of MR images. Methods: We introduce multiview Active Appearance Models for the automated segmentation of long-axis cardiac MR images of the left ventricle. Two modes of initialization were used to test the accuracy of the model with minimal user interaction and the best-obtainable accuracy with this model. The segmentation was initialized by annotating 2 points in the base and one in the apex. We tested the method's performance by comparing the point-to-curve errors, ejection fractions, and biplane area-length volumes calculated with the automatically detected contours to those calculated from contours that were annotated manually by experts. Leave-one-out experiments were performed with 2- and 4-chamber long axis MR images of 59 subjects in end-diastolic and end-systolic phases. Results: When initializing in all 4 frames, 97% of the segmentations were successful, and the standard deviation in the volume-errors with respect to the average manually identified volume was 9.0% for the end-diastolic volumes and 15% for the end-systolic volumes. When the method was initialized in the end-systolic frames only, 92% of the segmentations were successful, and the standard deviation in the errors in the volumes with respect to the average manually identified volume was 13.3% for the end-diastolic volumes and 16.7% for the end-systolic volumes. Bland–Altman plots showed that the errors were distributed randomly around 0, and by using a paired t test comparing manual and computer-determined volumes, we were able to detect that the volume differences were not significant. Simultaneous detection of the endocardial and epicardial contours in 2- and 4-chamber views and end-diastolic and end-systolic phases for one subject takes approximately 3 seconds. Conclusions: The accuracy of the reported method is comparable with the interobserver variability for initialization in all frames and slightly worse than the interobserver variability with initialization in the end-systolic frames only. However, in both cases the errors were not significant. Initialization in end-systolic frames only leads to a statistically insignificantly lower model accuracy; however, it requires only half the user interaction. Therefore, we can conclude that this method enables rapid analysis of the cardiac left ventricular function with little user interaction.Keywords
This publication has 17 references indexed in Scilit:
- Semiquantitative Assessment of Myocardial Perfusion Using Magnetic Resonance ImagingInvestigative Radiology, 2004
- Magnetic Resonance Imaging of Myocardial Perfusion and Viability Using a Blood Pool Contrast AgentInvestigative Radiology, 2004
- Determination of Cardiac Output With Multislice Spiral Computed TomographyInvestigative Radiology, 2004
- Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fractionJournal of the American College of Cardiology, 2000
- Model extraction from magnetic resonance volume data using the deformable pyramidMedical Image Analysis, 1999
- Deformable 2-D template matching using orthogonal curvesIEEE Transactions on Medical Imaging, 1997
- Model-based deformable surface finding for medical imagesIEEE Transactions on Medical Imaging, 1996
- Deformable models in medical image analysis: a surveyMedical Image Analysis, 1996
- Use of active shape models for locating structures in medical imagesImage and Vision Computing, 1994
- Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data.Radiology, 1993