Compatibility of intraocular lenses with blood and connective tissue cells measured by cellular deposition and inflammatory response in vitro
- 1 May 1992
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 18 (3) , 240-246
- https://doi.org/10.1016/s0886-3350(13)80900-5
Abstract
Injection molded poly(methyl methacrylate) (IM-PMMA), lathe-cut PMMA (LC-PMMA), heparin surface modified PMMA (HSM-PMMA), silicone, and polyhydroxyethyl methacrylate (polyHEMA) intraocular lenses (IOLs) were incubated with platelets, granulocytes, mouse macrophage-like RAW 264.7 cells and mouse fibrosarcoma L929 cells to examine their compatibility. The number of cells attached to the IOL was counted after the central IOL area (0.04 mm2) was photographed with an inverted light microscope. Cell morphology was examined by scanning electron microscopy (SEM). More platelets and granulocytes were attached to the IM-PMMA and silicone IOLs than to the HSM-PMMA and polyHEMA IOLs (P less than .05). RAW 264.7 and L929 cells grew on PMMA-based and silicone IOLs, whereas HSM-PMMA and polyHEMA IOLs did not support an abundant growth of these cells. Granulocytes were incubated with the IOLs in the presence of Luminol and the generation of chemiluminescence was measured. Poly(methyl methacrylate)-based IOLs caused granulocytes to release significant amounts of oxygen radicals, while the polyHEMA IOL was almost inactive in stimulating granulocytes. Silicone and HSM-PMMA IOLs showed an intermediate level of stimulating activity. The light intensity reached a peak within 14 minutes with the IM-PMMA IOL, and in about 18 minutes with the other IOLs. Our results suggest that IOL hydrophilicity prevents attachment of cells and that a hydrophilic, soft surface can discourage granulocyte stimulation.Keywords
This publication has 11 references indexed in Scilit:
- Intraocular PMMA lenses modified with surface-immobilized heparin: evaluation of biocompatibility in vitro and in vivoBiomaterials, 1989
- Experimental intraocular lens implantation in the rabbit eye and in the mouse peritoneal spaceJournal of Cataract & Refractive Surgery, 1988
- Experimental intraocular lens implantation in the rabbit eye and in the mouse peritoneal spaceJournal of Cataract & Refractive Surgery, 1988
- The Proteinaceous Coating and Cytology of Implant Lenses in RabbitsAmerican Journal of Ophthalmology, 1986
- Biomicroscopy of Surface Deposits Resembling Foreign-Body Giant Cells on Implanted Intraocular LensesAmerican Journal of Ophthalmology, 1985
- Cytopathology of Intraocular Lens ImplantationOphthalmology, 1985
- Complications of intraocular lenses. A historical and histopathological reviewSurvey of Ophthalmology, 1984
- Role of cell surface contact in the kinetics of superoxide production by granulocytes.Journal of Clinical Investigation, 1983
- The structure of heparin oligosaccharide fragments with high anti-(factor Xa) activity containing the minimal antithrombin III-binding sequence Chemical and13C nuclear-magnetic-resonance studiesBiochemical Journal, 1981
- Determination of platelet adhesion to polyethylene and heparinized surfaces with the aid of bioluminescence and 51chromium labelled plateletsThrombosis Research, 1977