A new method to analyze matrix-assisted laser desorption/ionization time-of-flight peptide profiling mass spectra
- 15 April 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (7) , 865-870
- https://doi.org/10.1002/rcm.1864
Abstract
In protein and peptide mass spectrometry in which profiling of peaks is involved, their masses and intensities are important characteristics. Because of the relative low reproducibility of peak intensities associated with complex samples in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), it is difficult to accurately assess the number of peaks and their intensities. In this study we evaluate these two characteristics for tryptic digests of cerebro-spinal fluid. We observed that the reproducibility of peak intensities was relatively poor (CV = 42%) and that additional normalization or spiking did not lead to a large improvement (CV = 30%). Moreover, at least seven mass spectra per sample were required to obtain a reliable peak list. An improvement of the sensitivity (i.e., eventually more peaks are detected) is observed if more replicates per sample are measured. We conclude that the reproducibility and sensitivity of peptide profiling can be significantly improved by a combination of measuring at least seven spectra per sample with a dichotomous scoring of the intensities. This approach will aid the analysis of large numbers of mass spectra of patient samples in a reproducible way for the detection and validation of candidate biomarkers.Keywords
This publication has 9 references indexed in Scilit:
- Diagnostic protein discovery using proteolytic peptide targeting and identificationRapid Communications in Mass Spectrometry, 2004
- Serum Peptide Profiling by Magnetic Particle-Assisted, Automated Sample Processing and MALDI-TOF Mass SpectrometryAnalytical Chemistry, 2004
- Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experimentsBioinformatics, 2004
- Urine protein profiling with surface-enhanced laser-desorption/ionization time-of-flight mass spectrometryKidney International, 2004
- Pattern analysis of serum proteome distinguishes renal cell carcinoma from other urologic diseases and healthy personsProteomics, 2003
- Quality Control and Peak Finding for Proteomics Data Collected from Nipple Aspirate Fluid by Surface-Enhanced Laser Desorption and IonizationClinical Chemistry, 2003
- A comprehensive approach to the analysis of matrix‐assisted laser desorption/ionization‐time of flight proteomics spectra from serum samplesProteomics, 2003
- A panel of cerebrospinal fluid potential biomarkers for the diagnosis of Alzheimer's diseaseProteomics, 2003
- Cystatin C as a cerebrospinal fluid biomarker for pain in humansPain, 2003