Importance of the sampling site for measurement of mixed venous oxgen saturation in shock
- 1 August 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 26 (8) , 1356-1360
- https://doi.org/10.1097/00003246-199808000-00020
Abstract
To determine if oxyhemoglobin saturation in blood samples taken from the superior vena cava or right atrium can be substituted for oxyhemoglobin saturation in blood taken from the proximal pulmonary artery (SvO2) in patients in shock. Prospective clinical investigation. Mixed surgical/medical intensive care unit in a university hospital. Thirty consecutive patients in severe circulatory shock who required insertion of a pulmonary artery flotation catheter (PAFC) immediately on intensive care unit admission. All patients fulfilled the criteria described below which were established in advance. Oxyhemoglobin saturation in the superior vena cava, right atrium, and pulmonary artery (SvO2) was measured by cooximetry in consecutive blood samples from each site during initial insertion of the PAFC. The mean standard deviation of values from these sites was similar: 74 +/- 12.5%, 70.6 +/- 13%, and 71.3 +/- 12.7%, respectively. However, when superior vena cava and right atrial oxyhemoglobin saturations and SvO2 were compared, the ranges and 95% confidence limits were found to be clinically unacceptable. The ranges were -19.3 to 23.1% and -19.7 to 16.7%, respectively, and the 95% confidence limits were -18.4 to 24.2% and -18.6 to +17.3%, respectively. These wide range differences and confidence limits would lead to large errors if superior vena cava or right atrial oxyhemoglobin saturations were substituted for true mixed venous blood in oxygen transport or pulmonary venous admixture calculations, or if clinical decision making was based on individual results. In patients in shock in whom clinical decisions may be based on the value of mixed venous oxyhemoglobin, oxyhemoglobin saturation is only reliably measured in samples taken from the pulmonary artery. (Crit Care Med 1998; 26:1356-1360)Keywords
This publication has 17 references indexed in Scilit:
- Report of the American-European consensus conference on ARDS: Definitions, mechanisms, relevant outcomes and clinical trial coordinationIntensive Care Medicine, 1994
- Does central venous oxygen saturation accurately reflect mixed venous oxygen saturation? Nothing is simple, unfortunatelyIntensive Care Medicine, 1992
- Mechanism of shock associated with right ventricular infarction.Heart, 1991
- Comparison of Central-Venous to Mixed-Venous Oxygen Saturation During Changes in Oxygen Supply/DemandChest, 1989
- Continuous Venous Oximetry in Surgical PatientsAnnals of Surgery, 1986
- Mixed Venous Oxygen SaturationArchives of internal medicine (1960), 1983
- COMPARATIVE STUDY ON THE CALCULATION OF INTRAPULMONARY RIGHT-TO-LEFT SHUNT USING CENTRAL VENOUS AND MIXED VENOUS BLOODCritical Care Medicine, 1981
- Errors in Sampling Pulmonary Arterial Blood with a Swan-Ganz CatheterAnesthesiology, 1974
- Central Venous Oxygen Saturation in ShockAnesthesiology, 1972
- Critical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac PatientsCirculation, 1969